Freestanding Gas Stove
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fi re
department.
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorized installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other fl am-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Owners &
Installation
Manual
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553-2000, NZS 5262
and have been certifi ed by the Australian Gas
Association for installation and operation as
described in these Installation and Operating
Instructions.
Your unit should be serviced annually by
an authorised service person.
918-533
Models: F37-NG
F37-LPG
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - Freestanding Gas Stove

05/18/06Freestanding Gas StoveFOR YOUR SAFETYWhat to do if you smell gas: Do not try to light any appli-ance Do not touch any electri-cal switch: do

Page 2 - 2 F37 Regency

10 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterINSTALLATIONDiagram 2HORIZONTAL INSTALLATIONSDiagram 1*Diagram 2: Local codes or regula

Page 3 - TABLE OF CONTENTS

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 11Diagram 5Diagram 4 Below Grade Snorkel Installation If the Snorkel Termination mus

Page 4 - DATA BADGE

12 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterSystem Data - F37Burner Inlet Orifi ce Sizes: NG LPG Burner

Page 5

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 13INSTALLATION CONVERSION KIT #731-968 FROM NG TO LPGUSING SIT 820 NOVA GAS VALVETHIS CONV

Page 6

14 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterINSTALLATIONC)02-44AERATION ADJUSTMENTThe burner aeration is factory set but may need ad

Page 7

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 15Diagram 2Diagram 34) The latches should already be at the proper setting. If they are

Page 8

16 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterINSTALLATIONOPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired. Conn

Page 9 - Horizontal Distance (meters)

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 17WARNING: Electrical Grounding InstructionsThis appliance is equipped with a three pronge

Page 10 - INSTALLATION

18 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterOPERATING INSTRUCTIONSOPERATING INSTRUCTIONS1) Read and understand these instructions b

Page 11

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 19COPY OF THE LIGHTING PLATE INSTRUCTIONS OPERATING INSTRUCTIONS1) Push in the gas con

Page 12

2 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterTo the New Owner:Congratulations! You are the owner of a state-of-the-art Regency® Rear

Page 13

20 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterMAINTENANCEPART OF CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.CAUTION

Page 14

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 21LATCH ADJUSTMENTThe door latch may require adjustment as the door gasket material compre

Page 15

22 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterMAINTENANCEREMOVING VALVEIf your valve requires maintenance or replace-ment, use the fo

Page 16

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 234) Remove the two outside frame pieces by removing two screws per side. See diagram be

Page 17

24 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterPARTS LIST 560-921 Louvre Assy (Set) - Nickel1) 560-920 Louvre Assy (Set) - Gold 560

Page 18 - OPERATING INSTRUCTIONS

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 2552606867686690929596989793949189697182835455577856BURNER & LOG ASSEMBLY52) 910-190

Page 19

26 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterDOOR ASSEMBLIES Part # Description PARTS LIST 730-923 Brush Nick

Page 20 - MAINTENANCE

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 27WARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind

Page 21

Printed in Canada© Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.

Page 22

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 3TABLE OF CONTENTSDATA BADGEData Badge ...

Page 23

4 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterThis is a copy of the label that accompanies each REGENCY Rear Flued Room Sealed Freestan

Page 24 - PARTS LIST

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 5INSTALLATION AND REPAIRS SHOULD BE DONE BY AN AU-THORIZED SERVICE PERSON. THIS APPLIANCE

Page 25

6 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterMake it a practice to have all of your gas appliances checked annually.13) Do not slam sh

Page 26

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 7INSTALLATIONEXTERIOR FLUE TERMINATION LOCATIONSMinimum clearances required for balanced fl

Page 27 - WARRANTY

8 F37 Regency® Rear Flued Room Sealed Freestanding Gas HeaterPLANNING YOUR FLUEING INSTALLATIONINSTALLATIONFLUEINGThe Regency® Room Sealed System (Hor

Page 28 - Printed in Canada

F37 Regency® Rear Flued Room Sealed Freestanding Gas Heater 9INSTALLATIONFLUEING ARRANGEMENTS - VERTICAL TERMINATIONS for both Residential & Manuf