FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-515MODELS: G36D-NG1 Natural Gas G36D-LP1 Propane12/1
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®10INSTALLATIONEXTERIOR VENT TERMINATION LOCATI
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace11VENTINGUltraGlow®UltraGlow®UltraGlow Direct Vent System (Flex)® Direct Vent System (Flex)®
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®12INSTALLATIONFPI946-506/P Vent Guard (Option
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace13Rigid Pipe Adaptor(Part# 510-994)Pipe LengthVerticalTerminalStorm Collar(Part # 953)Flashing
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®14RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace15INSTALLATIONRIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONSUltraGlow®UltraGlow®Ult
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®16RIGID PIPE VENTING ARRANGEMENTS - VERTICAL T
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace17INSTALLATIONThe G36D is approved for a maximum 37 ft. (11.3m) straight vertical, with Rigid
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®18INSTALLATIONVERTICAL TERMINATIONWITH CO-LINE
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace19INSTALLATIONVENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®2To the New Owner:Congratulations! You are the
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®20Diagram 46)The arrow on the vent cap s
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace21INSTALLATIONDiagram 3Diagram 5Diagram 1Diagram 2Note: Apply sealant "Mill-Pac" t
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®224) Separate the 2 halves of the wall thimbl
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace23INSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supp
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®24CONVERSION KIT #773-969 FROM NG TO LPG FOR G
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace25INSTALLATION20)Replace yellow "Natural Gas" label with red "Propane" lab
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®2628)Install the 1/2" bushing to the heat
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace275) Position Log 02-53 across the cutouts in Logs 02-75 and 02-51 with the notch on the le
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®28INSTALLATIONLog indentationPhoto shows rear
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace2910) Place the embers on the front of the burner tray in the places shown on the photos below
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace3TABLE OF CONTENTSOPERATING INSTRUCTIONSOperating ...
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®30Diagram 3Use the hook to pull the spri
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace31Thermostat Wire TableOption 3: WALL THERMOSTAT A wall thermostat may be installed if desired
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®32WIRING DIAGRAM This heater does not require
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace33120 Volt AC power is needed for the fan switch and blower. A three wire power cord is provi
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®34OPERATING INSTRUCTIONSOPERATING INSTRUCTIONS
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace35MAINTENANCE INSTRUCTIONS1) Always turn off the gas valve before cleaning. For relighting, r
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®36MAINTENANCE4) Make a periodic check of bur
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace3713) Undo the pilot tube from the valve with a 7/16" wrench.14) Undo the quick drop ou
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®38PARTS LISTG36D MAIN ASSEMBLY Part #
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace39G36D BURNER ASSEMBLY & LOG SET Part # Description52) 910-190 Piezo Ignitor &
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®4This is a copy of the label that accom
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®40PARTS LISTG36D FLUSH FRONT ASSEMBLY131) 510
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace41NOTES_______________________________________________________________________________________
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®42NOTES_______________________________________
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace43WARRANTYUltraGlow®UltraGlow®UltraGlow products, are designed with reliability and simp
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace44Installer: Please complete the following informationDealer Name & Address: ______________
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace5INSTALLATION CHECKLIST1) Check all clearances to combustibles. Refer to the following secti
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®6INSTALLATIONDiagram 1This includes:1) Clocki
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace7MANTEL LEG CLEARANCESCombustible mantel leg clearances as per diagram below:FRAMING AND
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace® G36D Zero Clearance Direct Vent Gas Fireplace®8INSTALLATIONCOMBUSTIBLE MANTELSBecause of the
UltraGlow® G36D Zero Clearance Direct Vent Gas Fireplace9"C" Screw Position:For a facing material depth of 1-1/4" (32mm), the top facin