Models: PG33-NGPG33-LPGOwners &InstallationPLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Manual03/11/10LISTINGS AND CODE APPROVALSThese gas
Regency PG33 Gas Inbuilt10INSTALLATIONEXTERIOR FLUE TERMINATION LOCATIONSMinimum clearances required for balanced fl ue terminals or the fl ue terminals
Regency PG33 Gas Inbuilt116-7/8"(173mm)dia. Flue pipe4" (102mm)dia. flue pipeWall Thimble (2 pc)(required inCanada only)Termination Cap(Part
Regency PG33 Gas Inbuilt12Termination CapWall Thimble 2 pieces(10" (254mm) Outer Diameter)2”x4”or2”x6”(21mm x 102mmor 21mm x 152mm)6-7/8"(17
Regency PG33 Gas Inbuilt13Pipe LengthVerticalTerminalStorm CollarFlashingCeiling Firestop24" (610mm)Pipe LengthAdj.Pipe Length11" - 14-5/8&q
Regency PG33 Gas Inbuilt14INSTALLATIONSIMPSON DURA-FLUE FLUEING COMPONENTS LISTAll Simpson Dura-Flue components are available directly from Regency.Al
Regency PG33 Gas Inbuilt15INSTALLATION• Flue must be supported at offsets.• Firestops are required at each fl oor level and whenever passing throug
Regency PG33 Gas Inbuilt16The PG33 is approved for a maximum 40 ft. straight vertical, with Simpson Dura-Flue Direct Flue GS fl ue systems for LPG, ULP
Regency PG33 Gas Inbuilt17FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONSSIMPSON DURA-FLUE DIRECT FLUE GS SYSTEM andREGENCY DIRECT FLUE SYSTEM (FLEX)
Regency PG33 Gas Inbuilt18FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONSSIMPSON DURA-FLUE DIRECT FLUE GS SYSTEM andREGENCY DIRECT FLUE SYSTEM (FLEX)
Regency PG33 Gas Inbuilt19Horizontal Flueing with Two (2) 90o ElbowsOption V H + H1 A) 0.3m Min. 0.9m Max. B) 0.
Regency PG33 Gas Inbuilt2TO THE NEW OWNER:Congratulations! You are the owner of a state-of-the-art Gas Stove by FPI FIREPLACE PRODUCTS INTERNATIONAL.
Regency PG33 Gas Inbuilt20Horizontal Flueing with Three (3) 90o ElbowsOption V H V + V1 H + H1 Min. Max. Min.
Regency PG33 Gas Inbuilt21INSTALLATIONVertical Flueing with Three (3) 90o Elbows Option V H + H1 V + V1 Mi
Regency PG33 Gas Inbuilt22Flex LinerExhaustFlueA maximumof two certifiedjoiner kitsmay be usedper length.#948-30535 ft (11m)Air IntakeCo-linear DVVert
Regency PG33 Gas Inbuilt23Flueing Arrangements - Vertical Terminations with Co-linear Flex System for bothResidential & Manufactured Homes into Ma
Regency PG33 Gas Inbuilt24Diagram 48) Slide the appliance and fl ue assembly to-wards the wall carefully inserting the fl ue pipe into the fl ue cap a
Regency PG33 Gas Inbuilt25INSTALLATIONDiagram 3: The upper half of the fl ashing is installed under the roofi ng material and not nailed down until the
Regency PG33 Gas Inbuilt26AERATION ADJUSTMENTThe air shutter can be adjusted by moving the adjusting wire up or down. The wire is accessed through the
Regency PG33 Gas Inbuilt27INSTALLATIONConversion Kit #436-969 for NG to LPGTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DO
Regency PG33 Gas Inbuilt28INSTALLATION23) Stick the conversion label "This unit has been converted to LPG" on the control box cover.24) Rev
Regency PG33 Gas Inbuilt29Conversion Kit #436-967 for NG to ULPGTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NO
Regency PG33 Gas Inbuilt3TABLE OF CONTENTSSafety LabelSafety Label... 4Installation Impor
Regency PG33 Gas Inbuilt3024) Reverse steps 22 and 17.25) Check venting confi guration on pages 17 & 18. 26) Turn on gas supply and plug in power c
Regency PG33 Gas Inbuilt31Conversion Kit #436-965 for NG to ULPG with Dedicated ULPG BurnerTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FI
Regency PG33 Gas Inbuilt3224) Reverse steps 22 and 17.25) Check venting confi guration on pages 17 & 18. 26) Turn on gas supply and plug in power c
Regency PG33 Gas Inbuilt33INSTALLATIONOPTIONAL BRICK PANELS1) Undo the bottom 2 door latches and open and remove glass door. Remove logs.2) Attach
Regency PG33 Gas Inbuilt34Diagram 1Diagram 3Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. R
Regency PG33 Gas Inbuilt35OPTIONAL BAY DOORThe Bay louvers MUST be usedwith the Bay glass option.The optional Bay door is an overlay on the fl ush fron
Regency PG33 Gas Inbuilt36INSTALLATIONBAY LOUVERS1) Remove fl ush louver top heat shield by removing the 4 screws.2) Install the bay louver top heat s
Regency PG33 Gas Inbuilt37INSTALLATIONWIRINGThis heater requires a 240V A.C. supply for the gas control to operate. A 240V A.C. power supply is needed
Regency PG33 Gas Inbuilt38OPERATING INSTRUCTIONSCOPY OF THE LIGHTING PLATE INSTRUCTIONS WARNING: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIAN
Regency PG33 Gas Inbuilt39OPERATING INSTRUCTIONSDuring the fi rst few fi res, a white fi lm may develop on the glass front as part of the curing proc
Regency PG33 Gas Inbuilt4SAFETY LABELThis is a copy of the label that accompanies each PG33 Gas Fireplace. We have printed a copy of the contents here
Regency PG33 Gas Inbuilt40FAN OPERATIONSet the fan speed on the control panel located in behind the bottom louvre.NORMAL OPERATING SOUNDS OF GAS APPLI
Regency PG33 Gas Inbuilt41MAINTENANCEGOLD-PLATED or BRASS LOUVERS/TRIMThe 24 carat gold-plated or brass fi nish on the louvers and trim requires little
Regency PG33 Gas Inbuilt42MAINTENANCE WARNING: Do not operate the appli-ance with the glass panels removed, cracked or broken. Replacement of the glas
Regency PG33 Gas Inbuilt43FAN REPLACEMENT1) Shut off the power supply.2) Remove the top louvre.3) Remove the glass door.4) Remove the 3 screws whi
Regency PG33 Gas Inbuilt44REMOVING VALVE TRAY1) Shut off the gas supply.2) Remove the louvres.3) Open the fl ush door and remove door.4) Remove the
Regency PG33 Gas Inbuilt45910-915910-082910-088910-089910-084910-526910-080910-521, 910-522, 910-523910-912910-906910-083910-916910-514PARTS LISTELECT
Regency PG33 Gas Inbuilt46PARTS LISTMain Assembly Part # Description Part # Description Part # Description
Regency PG33 Gas Inbuilt47Burner & Log Assembly Part Description 53) 430-055 Gasket - Valve Access Plate - NG
Regency PG33 Gas Inbuilt48PARTS LISTFlush Front & Louvers Part # Description Part # Description
Regency PG33 Gas Inbuilt49 430-930 Bay Front Complete106) 940-079/P Side Glass107) 936-243 Glass Gasket108) 940-078/P Center Glass110) * Bay Do
Regency PG33 Gas Inbuilt5INSTALLATIONIMPORTANT: SAVE THESE INSTRUCTIONSThe P33-NG or P33-LPG Direct Flue Fireplace must be installed in accordance wi
Regency PG33 Gas Inbuilt50NOTES
Regency PG33 Gas Inbuilt51WARRANTYExclusions:This limited Lifetime Warranty does not extend to or include paint, door or glass gasketing or trim. It
Printed in Canada© Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.
Regency PG33 Gas Inbuilt6INSTALLATION CHECKLIST1) Locate appliance a) Room location, page 6 b) Clearances to Combustibles, page 7 c) Mantle Cle
Regency PG33 Gas Inbuilt7COMBUSTIBLE MANTELSBecause of the extreme heat this fi replace emits, the mantel clearances are critical. Com-INSTALLATIONClea
Regency PG33 Gas Inbuilt816-1/2”(419mm)Minimum4"(102mm)3"(76mm)1-1/2"(38mm)30”(762mm)10" (254mm)dia. Hole throughwall for Dura-Ven
Regency PG33 Gas Inbuilt9For a facing material depth of 1-1/4"(32mm), the top facing support must be reversed.The Top Facing Support, the Side Na