03/11/10FOR YOUR SAFETYWhat to do if you smell gas: Do not try to light any appli-ance Do not touch any electri-cal switch: do not use any phone in
10Regency FG39-1 FireGenie Freestanding Gas StoveINSTALLATIONFLUEING ARRANGEMENTSVertical Terminations Using Dura-Flue Fluing System for Residential M
Regency FG39-1 FireGenie Freestanding Gas Stove11INSTALLATIONDV STOVE HORIZONTAL FLUE KIT (#946-112) INSTALLATIONMinimum Installation Height:FG39: 59-
12Regency FG39-1 FireGenie Freestanding Gas StoveINSTALLATION d) Cut the 2 ft. (.6m) section of rigid pipe to length. Ensure that the pipe length wh
Regency FG39-1 FireGenie Freestanding Gas Stove13DURA-FLUE TERMINATION KITPlanning Your Dura-Flue InstallationThere are two basic types of Dura-Flue R
14Regency FG39-1 FireGenie Freestanding Gas StoveDiagram 5Note: If installing termination on a siding covered wall, a vinyl siding standoff or furring
Regency FG39-1 FireGenie Freestanding Gas Stove15Diagram 11: The upper half of the fl ashing is installed under the roofi ng material and not nailed dow
16Regency FG39-1 FireGenie Freestanding Gas StoveINSTALLATIONOffset ChartDiagram 13 Notes: a) For multistorey vertical installations, a Ceiling Fire
Regency FG39-1 FireGenie Freestanding Gas Stove17INSTALLATIONGAS CONNECTIONThe gas line should be rigid pipe. Copper may also be used if approved by A
18Regency FG39-1 FireGenie Freestanding Gas StoveINSTALLATIONConversion Kit for NG to LPG Model #360-968THIS CONVERSION MUST BE DONE BY A QUALI
Regency FG39-1 FireGenie Freestanding Gas Stove19INSTALLATION12) Stick the conversion label "This unit has been converted to LPG" over top o
2Regency FG39-1 FireGenie Freestanding Gas StoveTo the New Owner:Congratulations! You are the owner of a state-of-the-art Regency Room Sealed Gas Sto
20Regency FG39-1 FireGenie Freestanding Gas StoveLOG SET INSTALLATIONRead the instructions below carefully and refer to the diagrams. If logs are bro
Regency FG39-1 FireGenie Freestanding Gas Stove21NotchE)02-45BracketA)02-65The bottom right edge of Log G)02-48 must sit snugly against the bracketSid
22Regency FG39-1 FireGenie Freestanding Gas StoveINSTALLATIONDiagram 1FRONT DOOR INSTALLATION(packaged separately)1) Open the two side panels.2) Sli
Regency FG39-1 FireGenie Freestanding Gas Stove23WIRINGCAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can ca
24Regency FG39-1 FireGenie Freestanding Gas StoveOPERATING INSTRUCTIONSFIRST FIREThe FIRST FIRE in your heater is part of the paint curing process. To
Regency FG39-1 FireGenie Freestanding Gas Stove25OPERATING INSTRUCTIONSNORMAL OPERATING SOUNDS OF GAS APPLIANCESIt is possible that you will hear some
26Regency FG39-1 FireGenie Freestanding Gas StoveCOPY OF THE LIGHTING PLATE INSTRUCTIONS WARNING: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIA
Regency FG39-1 FireGenie Freestanding Gas Stove27LOG REPLACEMENTThe unit should never be used with broken logs. Turn off the gas valve and allow the u
28Regency FG39-1 FireGenie Freestanding Gas StoveMAINTENANCEGLASS REPLACEMENTYour Regency heater is supplied with high tem-perature, 5mm Neoceram sili
Regency FG39-1 FireGenie Freestanding Gas Stove29MAINTENANCE4) Remove the two outside frame pieces by removing two screws per side. See diagram belo
Regency FG39-1 FireGenie Freestanding Gas Stove3UNIT SPECIFICATIONS
30Regency FG39-1 FireGenie Freestanding Gas StovePARTS LIST910-936910-082910-088910-089910-084910-527 / 910-935910-080910-521, 910-522, 910-523910-912
Regency FG39-1 FireGenie Freestanding Gas Stove31PARTS LIST25) * Flex Pipe (3" ID)26) * Clamp for Flex Pipe29) * Air Defl ector30) 730-019 R
32Regency FG39-1 FireGenie Freestanding Gas StoveBURNER & LOG ASSEMBLY57) * Switch Plate 736-574/P Valve Assembly - NG 736-576/P Valve Assemb
Regency FG39-1 FireGenie Freestanding Gas Stove33PARTS LISTDOOR ASSEMBLY Part # Description 101111107208111105WRA
34Regency FG39-1 FireGenie Freestanding Gas StoveNOTES________________________________________________________________________________________________
Regency FG39-1 FireGenie Freestanding Gas Stove35WARRANTYDISTRIBUTORS: Western Australia Eastern AustraliaAir Group AustraliaFireplace Products Austra
Printed in Canada© Copyright 2010 FPI Fireplace Products International Ltd. All rights reserved.
4Regency FG39-1 FireGenie Freestanding Gas StoveTABLE OF CONTENTSOperating InstructionsOperating Instructions ...
Regency FG39-1 FireGenie Freestanding Gas Stove5SAFETY LABELThis is a copy of the label that accompanies each REGENCY FG39 Freestanding Gas Stove. We
6Regency FG39-1 FireGenie Freestanding Gas StoveIMPORTANT: SAVE THESE INSTRUCTIONSThe REGENCY Room Sealed Freestanding Gas Stove must be installed in
Regency FG39-1 FireGenie Freestanding Gas Stove7INSTALLATION2) If required, adjusting the primary air to ensure that the fl ame does not carbon. First
8Regency FG39-1 FireGenie Freestanding Gas StoveLOUVER INSTALLATION1) Attach the top & bottom louvres to the side stove panel using 2 screws per
Regency FG39-1 FireGenie Freestanding Gas Stove9INSTALLATIONEXTERIOR FLUE TERMINATION LOCATIONSMinimum clearances required for balanced fl ue terminals