FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-523aMODELS: P42-NG4 Natural Gas P42-LP4 PropaneP42 Gas
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace10EXTERIOR VENT TERMINATION REQUIREMENTSINSTALLATIONA= Clearance above grade, veranda, porch,
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 116-7/8"(173mm) dia.Flue pipe4" (102mm)dia. flue pipeTermination CapPart #946-523/PA
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace124” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufacturers may not b
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 13DescriptionSimpsonDirect Vent Pro®Simpson Direct Vent GS®DiscontinuedSelkirk Direct-Temp™Ame
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace14Rigid Pipe Adaptor(Part# 510-994)Pipe LengthVerticalTerminalStorm CollarPart # 953Flashing943
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 15INSTALLATIONRIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONSREGENCY® DIRECT VENT S
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace16INSTALLATIONRIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONSREGENCY® DIRECT VENT SY
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 17INSTALLATIONRIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS(Propane & Natural Ga
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace18The P42 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft (3.7m) horizontal off
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 19Flex LinerExhaustFlueA maximumof two certifiedjoiner kitsmay be usedper length.#948-305 (35
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace2To the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by FI
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace20INSTALLATIONVENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for bothR
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 21INSTALLATIONBelow Grade InstallationIf the Snorkel Termination must be installed below grade
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace221) Maintain the 1-1/4"(32mm) clearances (air spaces) to combustibles when passing throug
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 23INSTALLATION3) Assemble the vent assembly by applying Mill Pac to the 4"(100mm) inner
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace24GAS LINE INSTALLATIONThe gas line can be brought through either the right or the left side of
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 25INSTALLATIONAERATION ADJUSTMENTThe aeration adjustment gears are located on the valve mounti
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace26LOG SET INSTALLATIONINSTALLATION5) Place the front logs in the unit, aligning the holes on t
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 27INSTALLATIONDiagram 1Diagram 3STANDARD FLUSH DOORThe standard fl ush door comes with a black
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace28BAY LOUVERS1) Install top louver by sliding the two bracket clips into the brackets located
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 29INSTALLATIONFULL SCREEN DOORS2) Remove the Screen Doors from the Full Screen Door Frame by
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 3TABLE OF CONTENTSOPERATING INSTRUCTIONSOptional Remote Control ...
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace30INSTALLATIONInnerCut-OutsBottom Flange NOTE: Should the fi nished wall protrude beyond the fa
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 31INSTALLATION10) Close screen doors.8) Slide the Top Grill into the louver brackets located
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace324-7/16"Openings forelectrical connectionsPower INMillivolt Wires5-1/2"1-1/2"WI
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 33INSTALLATIONFor PROPANE Units and Units Equipped with DC Spark Boxes
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace34OPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired, connect the wires as
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 35COPY OF THE LIGHTING PLATE INSTRUCTIONSOPERATING INSTRUCTIONS1) Push in gas control knob s
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace361) Push in gas control knob slightly and turn clockwise to "OFF". Knob cannot be t
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 37MAINTENANCEWARNINGThe use of substitute glass will void all product warranties.Do not operat
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace38REMOVING VALVE1) Shut off the gas supply.2) Remove the louvers (and bay door if it is on).3
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 39INSTALLING VALVE8) Reinstall the 12 hold down screws.9) Hook up the 2 TP and 2 TH wires to
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace4This is a copy of the label that accompanies each P42 Zero Clearance Direct Vent Gas Fireplace
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace40PARTS LISTP42 MAIN ASSEMBLY Part # Description Part #
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 41PARTS LISTP42 BURNER & LOG ASSEMBLY Part # Description
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace42P42 FLUSH DOOR & LOUVERS Part # Description 600-960 Flush Louvers (
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 43P42 BAY FRONT & LOUVERS 603-930 Bay Front Complete with Glass & Black Trim 106) 94
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace44NOTES________________________________________________________________________________________
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 45NOTES_______________________________________________________________________________________
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace46NOTES________________________________________________________________________________________
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 47WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In
Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 5REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the follow
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace614) Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 7Diagram 1INSTALLATIONUNIT SPECIFICATIONSThis includes:1) Clocking the appliance to ensure th
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace8MANTEL LEG CLEARANCESCombustible mantel leg clearances as per diagram below:MANTELSBecause of
Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace 9Position of Top Facing Supportfor material depth of 3/4” to 1-1/2"Top FacingSupportTOP A
Comments to this Manuals