FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4WARNING:If the information in these instructions are not follow
10Waterford TARA T25 Direct Vent Freestanding Gas StoveINSTALLATIONEXTERIOR VENT TERMINAL LOCATIONSA= Clearance above grade, veranda, porch, deck, or
Waterford TARA T25 Direct Vent Freestanding Gas Stove11INSTALLATIONRESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMESMINIUMUM HORIZONTAL TERMINATION IN
12Waterford TARA T25 Direct Vent Freestanding Gas StoveDiagram 4Diagram 2aDiagram 3HORIZONTALINSTALLATIONS1) Set the unit in its desired location. Ch
Waterford TARA T25 Direct Vent Freestanding Gas Stove13INSTALLATIONVERTICAL TERMINATION WITHCO-LINEAR FLEX SYSTEMThis appliance is designed to be atta
14Waterford TARA T25 Direct Vent Freestanding Gas StoveDV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATIONReview the following sequenc
Waterford TARA T25 Direct Vent Freestanding Gas Stove15DURA-VENTTERMINATION KITPlanning Your Dura-Vent InstallationThere are two basic types of Dura-V
16Waterford TARA T25 Direct Vent Freestanding Gas StoveINSTALLATIONfrom the rear of the unit to the wall. It is alsoimportant to note the wall thickne
Waterford TARA T25 Direct Vent Freestanding Gas Stove17INSTALLATIONRIGID PIPE VENTING COMPONENTS LISTAll Simpson Dura-Vent components are available di
18Waterford TARA T25 Direct Vent Freestanding Gas StoveINSTALLATIONRIGID PIPE VENTING - VERTICAL TERMINATIONSfor both Residential & Manufactured H
Waterford TARA T25 Direct Vent Freestanding Gas Stove19b) Horizontal runs of vent must be sup-ported every three feet. Wall strapsare available for th
2Waterford TARA T25 Direct Vent Freestanding Gas StoveWATERFORDTARA Direct Vent Freestanding Gas StoveTo the New Owner:Congratulations! You are the o
20Waterford TARA T25 Direct Vent Freestanding Gas StoveDiagram 9Diagram 8: The upper half of the flashing isinstalled under the roofing material and n
Waterford TARA T25 Direct Vent Freestanding Gas Stove21CATHEDRAL CEILINGSRound Support (RDS) &Square Support (SQS)If your home has a cathedral cei
22Waterford TARA T25 Direct Vent Freestanding Gas StoveConverting a Masonry ChimneyImportant: The existing masonry flueopening needs to have an area
Waterford TARA T25 Direct Vent Freestanding Gas Stove23Diagram 74) To determine the length of flex required,measure from 3" (76mm) above the top
24Waterford TARA T25 Direct Vent Freestanding Gas StoveCONVERSION KITFROM NATURAL GASTO PROPANEKit: #290-969 for TARA Gas Stoveusing SIT 820 NOVA Gas
Waterford TARA T25 Direct Vent Freestanding Gas Stove258) Unscrew the pilot orifice with the allen keyand replace with the LP pilot orifice in thekit
26Waterford TARA T25 Direct Vent Freestanding Gas StoveOPTIONALFRONT GRILL1) Remove the Cast Iron Front Panel. Catch thecast iron front panel at the b
Waterford TARA T25 Direct Vent Freestanding Gas Stove27OPTIONAL WALLTHERMOSTATA wall thermostat may be installed if desired.Connect the wires as per t
28Waterford TARA T25 Direct Vent Freestanding Gas StoveWIRING DIAGRAM - TARAThis heater does not require a 120V A.C. supply for operation. In case of
Waterford TARA T25 Direct Vent Freestanding Gas Stove29OPERATING INSTRUCTIONSOPERATINGINSTRUCTIONS1) Read and understand these instructionsbefore oper
Waterford TARA T25 Direct Vent Freestanding Gas Stove3TABLE OF CONTENTSConverting a Factory Built Metal Chimney ... 22High Elevation...
30Waterford TARA T25 Direct Vent Freestanding Gas StoveNORMAL OPERATINGSOUNDS OFGAS APPLIANCESIt is possible that you will hear some soundsfrom your g
Waterford TARA T25 Direct Vent Freestanding Gas Stove31MAINTENANCETop View of pilot flameMAINTENANCEINSTRUCTIONS1) Always turn off the valve before cl
32Waterford TARA T25 Direct Vent Freestanding Gas StoveValve Bracket with Valve - Top ViewScrewScrewScrewScrewStove FrontMAINTENANCEVALVE MAINTENANCEI
Waterford TARA T25 Direct Vent Freestanding Gas Stove33REPLACEMENT / SPARE PARTS LISTPARTS LIST1) W260021** Front Casting (Black)2) 280-022 Door3) W26
______________________________________________________________________________________________________________________________________________________
WARRANTYWaterford Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully
Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________
4Waterford TARA T25 Direct Vent Freestanding Gas StoveThis is a copy of the label that accompanieseach TARA Direct Vent Freestanding GasStove. We have
Waterford TARA T25 Direct Vent Freestanding Gas Stove5IMPORTANT:SAVE THESEINSTRUCTIONSThe TARA Direct Vent Freestanding Gas Stovemust be installed in
6Waterford TARA T25 Direct Vent Freestanding Gas Stovespecified vent and termination cap to theoutside of the building envelope. Never ventto another
Waterford TARA T25 Direct Vent Freestanding Gas Stove7OPTIONAL FANINSTALLATIONfor units starting with serial #11106 to 13347 / 217000001 to present.Fa
8Waterford TARA T25 Direct Vent Freestanding Gas StoveINSTALLATION9) Connect the red wire from the thermodisc to the red wire ofthe speed control wire
Waterford TARA T25 Direct Vent Freestanding Gas Stove9VENTINGINTRODUCTIONThe following vent systems in combination withthe Tara Direct Vent Freestandi
Comments to this Manuals