Regency C34 User Manual

Browse online or download User Manual for Kiln Regency C34. Regency C34 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 5
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
C34 Freestanding Direct Vent Gas Stove
Gas Line In
J
C
I
H
Gas Line In
A
B
D
F
G
E
K K
L
Back wall
Wall
Side wall
Side wall
Wall
N
M
P
P
O
O
Model C34-NG3 C34-LP3
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5.0” W.C. (1.25 kPa) 12.0” W.C. (3.00 kPa)
Manifold Pressure - High 3.82” W.C. (0.95 kPa) 11” W.C. (2.74 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orifi ce Size #36 #52
Minimum Input 16,000 BTU/h 16,000 BTU/h
Maximum Input 32,000 BTU/h 32,000 BTU/h
Vent Sizing 4” Inner / 6-5/8” Outer 4” Inner / 6-5/8” Outer
C34 Gas Stove
Dimension Description C34
A Unit Width 24” (610mm)
B Unit Height 29-11/16” (737mm)
C Unit Depth 21-5/8” (549mm)
D Pedestal Height 11-3/4” (298mm)
E Cast Leg Height
(including Bottom shield) 11-3/4” (298mm)
F Bottom shield Height 4” (102mm)
G Vent centerline to Side 12” (305mm)
H Vent centerline to Back 7” (178mm)
I Gas Line Height (from base) 9” (229mm)
J Side to Gas Line 4-1/2” (114mm)
Alcove clearances
Dimension Description C34
K Side Wall to Unit 10” (250mm)
L Back Wall to Unit 6” (150mm)
M Side wall to Vent Centerline 22” (559mm)
N Back wall to Vent Centerline 13” (330mm)
Corner Clearances
Dimension Description C34
O Wall to Unit Corner 1.5” (38mm)
P Wall to vent centerline 14” (356mm)
Minimum ceiling height is 36" (914mm) from top of unit.
Minimum clearance to vent is 1-1/4” (32mm).
The above listed clearances are minimum distances to combustible
materials. When installing on carpet or vinyl fl ooring the bottom pedestal
cover plate must be installed.
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems: Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent
Security Secure Vent®
Selkirk Direct-Temp.
145June 2007 Regency Product Specifi cations Book
Gas Stoves
Gas Stoves
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - Gas Stoves

C34 Freestanding Direct Vent Gas StoveGas Line InJCIHGas Line InABDFGEK KLBack wallWallSide wallSide wallWallNMPPOOModel C34-NG3 C34-LP3Fuel Type Natu

Page 2

Min. 12"*(305mm)AdequatedrainageWindowWellGravelDura-VentSnorkelC34 Gas StovePipe LengthAdapterTrim CollarTrimCollar4" ID LinerSpacerSpringA

Page 3

Vent Restrictor PositionVent restriction is required for certain venting installations, see the diagrams in "Venting Arrangement" section to

Page 4

C34 Gas StoveVenting Arrangements - Vertical TerminationsRigid Pipe System(Propane & Natural Gas)The C34 is approved for a maximum 30 ft. straigh

Page 5

C34 Gas StoveVenting Arrangements - Horizontal TerminationsThis diagram shows all allowable combinations of vertical runs with horizontal terminations

Comments to this Manuals

No comments