Model H300
Optimum Effi ciency 74%
Emissions (grams/hr) EPA Certifi ed 4.1 grams/hr
Maximum BTU* 45,500 BTU
Maximum Log Size 18”
Firebox Size 1.71 cu. ft.
Flue Size 6”
Burn Time (typical)* up to 8 hrs.
* Length of burn time and BTU Range depends on type of wood, climate conditions and
installation.
97June 2007 Hampton Product Specifi cations Book
Wood Stoves
Wood Stoves
H300 Wood Stove
Residential Installation “C” Vent (Single Wall)
Unit (with heat Shield)
From Unit From Corner
From Vent
centerline
ABCDE F
H300 17” 15” 13” 30” 15” 19”
Minimum Clearance To Combustible
Materials
Please read the section below carefully as clearances depend on whether
the airmate or the rear heat defl ector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side
wall or to a corner, and from the rear heat shield to a back wall.
Minimum clearance with side load door in use is 18” (457mm) to side
wall or refer to dimension (A) if the side load door is not used.
26" (660mm)
6-1/4"
(158mm)
27” (686mm)
16-1/2” (420mm)
15” (381mm)
16-1/8” (406mm)
24” (610mm)
7-1/8”
(178mm)
30-1/4” (762mm)
27-1/4” (692mm)
29-3/4” (737mm)
27” (686mm)
25-1/2” (648mm)
14-7/8”
(378mm)
6”
(152mm)
6”
(152mm)
1-1/4”
(32mm)
Cast Side Shelf
(Optional)
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required
from the stove collar to the ceiling level.
Unit (with heat Shield)
From Unit From Corner
From Vent
centerline
ABCDE F
H300 15” 10” 9” 28” 10” 15”
H300 Cast Freestanding Woodstove