FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-522b12/04/08P36D-1 Zero ClearanceDirect Vent Gas Firep
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace10INSTALLATIONThe HeatWave Duct Kit and the Heat Release Kit have different clearance and framing
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 11INSTALLATIONClearances for Bay Front, Flush Front& Full Screen DoorsClearances for Barcelona
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace12Drywall12" Mantel7 1/2" Mantel3 1/2"MantelMantel Clearances withFlush Glass / Full
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 13REGENCY® SERIES COMBUSTIBLE MANTEL CLEARANCESBecause of the extreme heat this fi replace emits,
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace14These drawings are to scale at 1:6 (one inch = 6 inches)Mantel can be installed anywhere in shade
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 15These drawings are to scale at 1:6 (one inch = 6 inches)Mantel can be installed anywhere in shad
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace16INSTALLATIONREGENCY® MANTEL LEG CLEARANCESCombustible mantel leg clearances as per diagram:Maximu
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 17Framing Dimensions A B C D 36-1/4" 37-1/4" 17-3/8" 46-1/2"
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace18SteelStudSteelStudMin. 12"(305mm)Min. 6"(153mm)Min. 6"(153mm)37-1/4"(946mm)30
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 19"C" Screw Position:For a facing material depth of 1-1/4" (32mm), the top facing s
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace2To the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by FPI FI
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace20EXTERIOR VENT TERMINATION LOCATIONSA= Clearance above grade, veranda, porch, deck, or balcony *(
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 21VENTINGDirect Vent System (Flex) Horizontal Terminations OnlyThese venting systems, in combinat
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace22INSTALLATION4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufacturers m
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 23DescriptionSimpsonDirect Vent Pro®Selkirk Direct-Temp™American Metal Products®Amerivent DirectMe
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace24Rigid Pipe AdaptorPipe LengthVerticalTerminationCapStorm CollarFlashingCeiling Firestop24" P
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 25INSTALLATION VENTING ARRANGEMENTS HORIZONTAL TERMINATIONRIGID PIPE AND FPI DIRECT VENT SYSTEM (
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace26INSTALLATION• Vent must be supported at offsets.• Firestops are required at each fl oor level
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 27The P36D-1 is approved for a 40 ft. straight vertical, with rigid pipe vent systems for Propane
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace28INSTALLATIONHORIZONTAL VENTING WITH TWO (2) 90O ELBOWSHORIZONTAL VENTING WITH THREE (3) 90O ELBOW
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 29VH1HV1INSTALLATIONVERTICAL VENTING WITH TWO (2) 90O ELBOWSVERTICAL VENTING WITH THREE (3) 90O EL
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 3TABLE OF CONTENTS4” x 6-5/8” Rigid Pipe Cross Reference Chart ...22Rigid Pipe Venting S
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace30INSTALLATIONVERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEMTHE APPLIANCE MUST NOT BE CONNECTED TO
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 31INSTALLATIONVENTING ARRANGEMENT - VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREP
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace32Diagram 46) The arrow on the vent cap should be pointing up. Insure that the 1-1/2" clearan
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 33INSTALLATIONDiagram 3Diagram 5Diagram 1Diagram 2NOTE: For best results and optimum performance
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace344) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the ou
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 35INSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping s
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace36INSTALLATIONTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERIF IN DOUBT DO NOT DO THIS CONV
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 37INSTALLATIONInstallation of the DC Sparker:16) Verify that if the conversion is from NG to LPG,
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace38INSTALLATION27) Run the other end of the ground wire and DC spark generator wires through the bu
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 39INSTALLATION 1) Undo the bottom 2 door latches and open and remove glass door. Remove logs.Not
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace4TABLE OF CONTENTSOPERATING INSTRUCTIONSOperating Instructions ...
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace40INSTALLATIONLOG SET INSTALLATION NotchBracketBracket02-5102-7502-513) Place the Log 02-75 on t
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 41Rear Bracket02-5502-7502-537) Place the bottom left front edge of Log 02-55 against the rear b
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace42Log IndentationPhoto shows rear grate tab. Log 02-51 was removed to show the positioning of Log 0
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 43Place embers in these 3 locations on the burner tray.02-5002-5502-7502-5302-5102-5402-5210) Pla
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace44Diagram 3Use the hook to pull the spring out until you can put the hook into the slot on the bott
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 4514 GA.16 GA.18 GA.20 GA.22 GA.50 Ft.32 Ft.20 Ft.12 Ft.9 Ft.Recommended Maximum Lead Length (Two-
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace46WIRING DIAGRAMS Caution: Ensure that the wires do not touch any hot surfaces and are away fr
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 47For PROPANE Units and Units Equipped with DC Spark Boxes**For installation of the DC Spark Box r
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace48OPTIONAL FAN INSTALLATION120 Volt AC power is needed for the fan switch and blower. The fan can b
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 49OPERATING INSTRUCTIONSIMPORTANT Gas on/off knob cannot be turned from "PILOT" to "
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 5This is a copy of the label that accompanies each P36D-1 Zero Clearance Direct Vent Gas Fireplace
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace50MAINTENANCE INSTRUCTIONS1) Always turn off the gas valve before cleaning. For relighting, refer
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 51MAINTENANCENote: Never operate the appliance without the glass properly secured in place.6) Do
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace5211) Undo the pilot tube from the valve with a 7/16" wrench.12) Undo the quick drop out ther
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 53FLUSH LOUVERS 1) Install the top louver by sliding the two bracket clips into the brackets l
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace54REGENCY® OPTIONSBAY TRIMAttach supplied magnets each to the back of the top and bottom trim piece
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 55REGENCY® OPTIONSFULL SCREEN DOOR INSTALLATION1) Before beginning the installation, remove th
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace56REGENCY® OPTIONS3) Install the hinges to the hinge brackets on the left and right side of the bo
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 57REGENCY® OPTIONSWhen installing the optional Tripoli Screen Door Series, a non-combustible mater
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace58REGENCY® OPTIONSNote: The facing material has to go on after the unit is set. 1) Remove Glass Doo
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 59Note: The Nailing Strips can be adjusted, depending on the facmaterial (as indicated in Diagram
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace6REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following a
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace60REGENCY™ SERIES OPTIONSTHE KENSINGTON® FRONT INSTALLATION1) Bend tabs downwards located at the b
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 61REGENCY™ SERIES OPTIONSTHE BALMORAL® FRONT INSTALLATION6) For optional fan installation, see &q
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace62THE KENSINGTON® & BALMORAL FRONT2-PANEL DOOR INSTALLATION3-PANEL DOOR INSTALLATIONREGENCY™ SE
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 63THE KENSINGTON, BALMORAL FRONT OPTIONAL FAN INSTALLATION1) Remove fan cover by undoing screw.2)
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace64HAMPTON® OPTIONSHAMPTON® CAST FACEPLATE1) Remove top louver and grill.2) Open bottom louver and
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 651) Remove the 3 faceplate mounting phillips head screws from the inside top of fi rebox, and dis
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace66PARTS LISTMAIN ASSEMBLY Part # Description Part # Descript
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 67BURNER ASSEMBLY & LOG SET Part # Description 52) 910-190 Piezo Ignitor & Nut5
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace68PARTS LISTREGENCY® BAY FRONT ASSEMBLY Part # Description Part # Descript
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 69PARTS LISTREGENCY® FLUSH FRONT ASSEMBLY Part # Description Part # Descriptio
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 736" (914mm)33"(838mm)INSTALLATION36"(914mm)30-1/2"(775mm)37"(940mm)17-1/
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace70PARTS LISTHAMPTON® CAST FACEPLATE & GRILL ASSEMBLY Part # Description
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 71WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addi
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace72Installer: Please complete the following informationDealer Name & Address: __________________
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace8INSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe P36D-NG1 or P36D-LP1 Direct Vent Fireplac
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace 9INSTALLATIONDiagram 1This includes:1) Clocking the appliance to ensure the correct fi ring rate (