Regency 4720 Installation Manual

Browse online or download Installation Manual for Mobile phones Regency 4720. Regency 4720 Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 100
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
R E G E N C Y
Model 4720 Control/Communicator
Installation Manual
Part Number 150476, Rev. A
Initial Release Date: March 1995
Revised October 1998
Page view 0
1 2 3 4 5 6 ... 99 100

Summary of Contents

Page 1 - Installation Manual

R E G E N C YModel 4720 Control/CommunicatorInstallation ManualPart Number 150476, Rev. AInitial Release Date: March 1995Revised October 1998

Page 2 - 2266 Second Street N orth

List of FiguresviiiRegency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Connecting the Supervised Siren M

Page 3 - FCC Part 68

90Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98YYR0 code . . . . . . . . . . . . . . . . . . . 72

Page 4 - Table of Contents

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9811 IntroductionThe ITI® Model 4720 is a combination

Page 5

2Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98• Model 4150 External Control Module.This module ma

Page 6

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9834. This device cannot be adjusted or repaired in th

Page 7

4Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/984. The Bell Test at Arming option or the Ringback a

Page 8

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9852.3.4 NFPA 72 Central Station Signaling andLocal Pr

Page 9 - List of Tables

6Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/987. All unused knockout holes must be plugged using

Page 10 - List of Figures

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9872.3.6 Fire System Test Procedure for UL 985 Systems

Page 11 - Introduction

8Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Figure 3a: 4720 Printed Circuit Board, Revision L

Page 12 - Preconnection Requirements

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/989Figure 3b: 4720 Printed Circuit Board, Prior to Re

Page 13 - WARNING:

Visit our website at www.ititechnologies.comITI and Regency are registered trademarks of Interactive Technologies, Inc.ITI © 1998. All rights reserved

Page 14 - 8457G30B.DSF

10Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/983.1 Battery CablesThe red (+) and black (–) batter

Page 15

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98113.3.2 FusesPC board revisions prior to Revision L

Page 16

12Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/983.6 AC Power LightThe green AC power light is on w

Page 17 - Control Panel Description

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9813Be sure to maintain a physical separation of at le

Page 18 - Revision L

14Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/983.12 Jumper Blocks and Jumper WiresNote: Starting

Page 19 - Prior to Revision L

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98153.13 Plug-On Terminal StripsThe Model 4720 uses pl

Page 20 - CAUTION:

16Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/983.14 Model 4720 Terminal Strip Description* Note 1

Page 21 - FAST-BLOW

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98173.15 Non-UL Wiring DiagramFor UL installations, re

Page 22

18Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/984 4720 Control Panel Overview4.1 Current Draw Calc

Page 23

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98194. Add up each of the two To t a l columns and wr

Page 24 - 3.12.3 Jumpers J3 and J4

iNoticesRegency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98FCC Part 15 Information to the UserChanges o

Page 25 - 3.13.1 Terminal Strip Removal

20Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/984140 Intercom/Tele-phone Controller2F2(1 max.)× 10

Page 26

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98214.1.2 Current Draw on Protective Devices Indicated

Page 27 - 3.15 Non-UL Wiring Diagram

22Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/984. Subtract the second value in Column 3 from the

Page 28 - 4720 Control Panel Overview

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98234.2 System Planning Block DiagramFigure 4.2a: Mod

Page 29

24Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/985 Wiring PrecautionsTo avoid induced noise (transf

Page 30

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98256.2 Mounting the Model 4720Mount the Model 4720 so

Page 31 - 181 Installa

26Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/986.3.2 Installing the TransformerThe main wiring di

Page 32 - Column 1 Column 2 Column 3

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9827Figure 6.3.2a: Model 9220 Transformer Connection6

Page 33 - System Planning Block Diagram

28Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Figure 6.4a: Wiring the Model 4195 Auxiliary Powe

Page 34 - Wiring Precautions

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98297.2 Wiring the TouchpadsAll touchpads require four

Page 35 - 6.2 Mounting the Model 4720

Table of ContentsiiRegency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/981 Introduction . . . . . . . . .

Page 36 - DO NOT SHORT

30Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/987.4 Setting ID CodesWhen installing the system, se

Page 37

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98317.6 Mechanical KeyswitchA normally open mechanical

Page 38 - Touchpad Installation

32Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/989.1 Normally Open and Normally Closed Contact Wiri

Page 39 - 7.3 Daisy-Chaining Touchpads

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9833Figure 9.2a: ESL 445AT Smoke Detector Wiring9.3 M

Page 40 - 7.5.2 Wiring the Model 4203

34Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98See Table 4.1.1.0a (Section 4.1: Current Draw Calc

Page 41 - 0476G11A.DSF

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9835Figure 10.1.1a: Auxiliary Power for Supervised Be

Page 42 - 9.2 Smoke Detector Wiring

36Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Figure 10.2a: Commercial Bell Wiring10.3 External

Page 43 - Local Annunciation

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/983710.4 Internal Speaker WiringIf an internal speaker

Page 44

38Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9811 Telephone Line Connection11.1 Line 1 WiringThe

Page 45 - 0476G15A.DSF

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/983911.3 External Dialer Failed IndicatorA 12-VDC devi

Page 46 - 10.3 External Speaker Wiring

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98iii3.12 Jumper Blocks and Jumper Wires . . . . . .

Page 47 - 10.5 Model 4180 Status Relays

40Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9811.4.2 Model 4175 OperationThe 4720 will always tr

Page 48 - Telephone Line Connection

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9841Figure 12.1.1a: Wiring the Model 4110 Serial Zone

Page 49 - 11.4.1 Model 4175 Wiring

42Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98The Model 4110 has two (2) serial loops. Each loop

Page 50 - Expansion Zones

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/984312.1.2 Determining ID Numbers and Zone Numbers12.1

Page 51

44Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9812.2 Model 4115 Serial Zone ExpanderThe Model 4115

Page 52

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9845Figure 12.3.1b shows how to wire the Model 4125 to

Page 53

46Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9812.3.2 Determining 4125 Zone Expander's Input

Page 54 - 12.3.1 Model 4125 Zone Wiring

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9847Figure 12.4.1a: Wiring the Model 4130 RF Zone Exp

Page 55

48Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98The Model 4184 Watchdog Module is installed in the

Page 56

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9849Figure 14.1a: Connecting the Model 4140 to the Mo

Page 57 - Model 4184 Watchdog Module

ivRegency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9810.4 Internal Speaker Wiring . . . . . . . . . .

Page 58 - Other Expansion Devices

50Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Figure 14.1.1a: Model 4640 Audio Module14.1.2 Mou

Page 59

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9851The Model 4640 has a microphone gain adjustment lo

Page 60

52Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9814.1.4 7381 Connecting the Model 4140 to the Model

Page 61 - 0476G31A.DSF

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/985314.2 Model 4150 Environment ControlSee the Model 4

Page 62 - Table 14.1.4a: Wiring Table

54Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Figure 14.4b: Model 7367 with Model 4640 Speaker

Page 63 - 14.3 Printing Devices

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/985515 Touchpad OperationThe following paragraphs desc

Page 64

56Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9815.1 LED Indications15.1.1 LEDs on Left Side (Behi

Page 65 - Touchpad Operation

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9857The touchpad speakers will also beep when:• A key

Page 66 - 15.2.1 Touchpad Alert Tones

58Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98BYPSThis key is used to bypass (deactivate) indivi

Page 67 - 15.3 Keys

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/985916 Touchpad Functions16.1 Viewing StatusWhen the S

Page 68

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98v15.2 Audible Alarms . . . . . . . . . . . . . . .

Page 69 - Touchpad Functions

60Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9816.4.2 To Clear MemoryTo clear the alarm memory, p

Page 70

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/986116.10.2 CODE 2 key (Code 2 Residential Touchpads O

Page 71 - Table 16.12a: Test Modes

62Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9816.12.4 Request DownloadThis mode causes the diale

Page 72 - 16.12.8 Set Date Mode

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/986316.12.9 Set Time ModeWhen you first apply power to

Page 73 - Digit Day

64Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9816.13.5 Do Not DisturbAs of Revision 880515 of the

Page 74

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/986517 Preprogrammed EEPROM17.1 Factory-Programmed Opt

Page 75 - Preprogrammed EEPROM

66Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9817.1.5 Timers:Aud Shutdown = 9 (9 × 10 = 90 second

Page 76

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/986718 Programming18.1 Model 4720 Downloading (with 55

Page 77 - Programming

68Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9818.2 Model 5520 Field ProgrammerFigure 18.2a shows

Page 78 - Model 5520 Programmer Menus

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/986919 Touchpad ProgrammingAll options can be addresse

Page 79 - Touchpad Programming

viRegency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9817 Preprogrammed EEPROM . . . . . . . . . . . . .

Page 80 - Model 4720 reporting Formats

70Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9820 Area Control OperationRefer to the Model 4721 A

Page 81 - Other codes:

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9871FSK & SK 4/2 CodeDescription RadionicsBFSK Cod

Page 82 - SIA Reporting Format

72Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9822 SIA Reporting Format9000 Printer Code Status of

Page 83

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9873The Model 4720 is compatible with the following UL

Page 84 - Trouble/Error Messages

74Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9823 Trouble/Error MessagesThe following paragraphs

Page 85 - Troubleshooting

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9875DOOR (1 - 15)Indicates a door has been left open (

Page 86

76Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Next, use a clip wire and short the two (2) wires

Page 87 - Program As System Response

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/987725.2 LCD Operational ChangesWith Revision N, if an

Page 88 - ONE YEAR LIMITED WARRANTY

78Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9826 REGENCY® ONE YEAR LIMITED WARRANTYInteractive T

Page 89

Index79Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Symbols# Rings option . . . . . . . . . . .

Page 90

List of TablesviiRegency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Red LED Indications . . . . . . . .

Page 91

80Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98reporting codes for . . . . . . . . . . . . 71rese

Page 92

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9881clock speed adjustment . . . . . . . . . . . . 12C

Page 93

82Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98Digit reported zone . . . . . . . . . . . . . . 70

Page 94

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9883Expansion restore . . . . . . . . . . . . . . . 71

Page 95

84Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98IICOM key. . . . . . . . . . . . . . . . .58, 63IC

Page 96

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9885memory location #1. . . . . . . . . . . . . . 64me

Page 97

86Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98OR 0 - 99 codes . . . . . . . . . . . . . . . 72Os

Page 98

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9887reportingalarms . . . . . . . . . . . . . . . . .

Page 99

88Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/98sprinkler codes . . . . . . . . . . . . . . . . 7

Page 100

Regency® Model 4720 Control/Communicator Installation Manual (P/N 150476, Rev. A) Revised 10/9889transmitters, RF type . . . . . . . . . . . . . 13

Comments to this Manuals

No comments