10Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONAlcoveCaution RequirementsThe top, back and sides of the fi replace are defi ned by standoffs. The
Regency Bellavista™ B36XTE Gas Fireplace11INSTALLATIONMANTEL CLEARANCESNote: Ensure the paint that is used on the mantel and the facing is "High
12Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONMANTEL LEG CLEARANCESNON- COMBUSTIBLE REQUIREMENTS:Min. 7"(178mm)Min. 3”(76mm)42-1/4"(
Regency Bellavista™ B36XTE Gas Fireplace13INSTALLATIONFRAMING MNOQPRUVTOpening for gasconnection11" (279mm)dia. Hole throughwall Vent.Non-Combust
14Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONFINISHINGNon-combustibleMaterialJ-style Trimor metal corner beadmay be used to finish theseedges
Regency Bellavista™ B36XTE Gas Fireplace15INSTALLATIONUNIT ASSEMBLY PRIOR TO INSTALLATIONBEFORE YOU STARTThe Top Facing Support, the Side Nailing Stri
16Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONCONVERSION TO TOP VENTNote: This conversion must be done prior to the unit being placed in posi
Regency Bellavista™ B36XTE Gas Fireplace17INSTALLATION7) From the outside top of the fi rebox - remove the intake cover plate by removing the 4 - 1/4
18Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONVENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATIONNOTE: THE VENT RESTRICTOR & BAFFLE
Regency Bellavista™ B36XTE Gas Fireplace19INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTSMinimum Clearance RequirementsCanada1USA2A Clearance above
2Regency Bellavista™ B36XTE Gas FireplaceTo the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The Bell
20Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Amerivent DirectMeta
Regency Bellavista™ B36XTE Gas Fireplace21INSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Amerivent DirectMeta
22Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONAdjustable Length 3”-10”-Galvanized N/A N/A 5DAL TC-5DLTAdjustable Length 3”-10”-Black N/A N/A 5
Regency Bellavista™ B36XTE Gas Fireplace23INSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™Metal-Fab™Sure SealICC Excel DirectAttic In
24Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONThe Diagrams show all allowable combinations of vent runs with 5" x 8" venting using t
Regency Bellavista™ B36XTE Gas Fireplace25INSTALLATIONHORIZONTAL TERMINATIONSFLEX VENT 5" X 8" These venting systems, in combination with th
26Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONRigid Pipe AdaptorPipe Length90 ElbowoHorizontalTerminationCapWall ThimbleVinyl SidingStandoff (
Regency Bellavista™ B36XTE Gas Fireplace27INSTALLATIONRigid Pipe AdaptorPipe LengthAstrocapXLWall ThimbleVinyl SidingStandoff(Optional)45 elbow053”75”
28Regency Bellavista™ B36XTE Gas FireplaceINSTALLATION1622001212661818449"(1245mm)MinimumHeightRequirement414881010 14 161818 20Vertical Height (
Regency Bellavista™ B36XTE Gas Fireplace29INSTALLATIONPipe LengthVerticalTerminationCapStorm CollarFlashingCeiling FirestopRigid Pipe AdaptorPipeLengt
Regency Bellavista™ B36XTE Gas Fireplace3MANUFACTURED MOBILE HOME REQUIREMENTSINFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALEThis Regency®
30Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONHORIZONTAL TERMINATIONSTWO (2) 90O ELBOWS (RIGID PIPE 4" X 6 - 5/8")HH1VOption V
Regency Bellavista™ B36XTE Gas Fireplace31INSTALLATIONVENTING ARRANGEMENTS FOR VERTICAL TERMINATIONSRIGID PIPE 4" X 6-5/8"(MUST USE REDUCER
32Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONVH1HV1VERTICAL TERMINATIONS THREE (3) 90O ELBOWS (RIGID PIPE 4" X 6 - 5/8") Option
Regency Bellavista™ B36XTE Gas Fireplace33INSTALLATIONVENTING ARRANGEMENTSWITH CO-LINEAR FLEX SYSTEMTHE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY F
34Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONVERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL & M
Regency Bellavista™ B36XTE Gas Fireplace35INSTALLATIONSchéma 7Schéma 57) Ensure that the pipe clearances to combustible materials are maintained (Sc
36Regency Bellavista™ B36XTE Gas FireplaceINSTALLATION1) Locate the unit in the framing, rough in the gas (preferably on the right side of the unit).
Regency Bellavista™ B36XTE Gas Fireplace37INSTALLATIONGAS LINE INSTALLATIONThe gas line is brought through the right side of the appliance. The gas va
38Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by clo
Regency Bellavista™ B36XTE Gas Fireplace39INSTALLATIONCONVERSION KIT #576-972 FROM NG TO LPfor B36XTE using SIT 886 NOVA Gas ValveTHIS CONVERSION MUST
4Regency Bellavista™ B36XTE Gas FireplaceTABLE OF CONTENTSSAFETY LABELCopy of Safety Decal ...5REQUI
40Regency Bellavista™ B36XTE Gas FireplaceINSTALLATION15) Remove Hi/Lo pressure regulator by removing 2 screws as shown below. Reverse steps to inst
Regency Bellavista™ B36XTE Gas Fireplace41INSTALLATIONDangerous operating conditions may occur if the panels are broken.Handle with care. DO NOT FORCE
42Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONOPTIONAL STAINLESS STEEL / BLACK ENAMEL PANEL INSTALLATION1) Remove the heat defl ector by removi
Regency Bellavista™ B36XTE Gas Fireplace43INSTALLATION5) Repeat step 4 for left side panel.5) Repeat step 4 for left side panel.6) Reverse step 1.6) R
44Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONLOG SET INSTALLATIONInstallation of Optional Panels must be completed before installing the log
Regency Bellavista™ B36XTE Gas Fireplace45INSTALLATIONBEABDNotch location on undersideof Log A (runs from back - front)Right Peg - Log E6) Position Lo
46Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONC3rd Grate PostNotch in log CLeft Peg - Log E8) Place the lava rocks on the front of the burne
Regency Bellavista™ B36XTE Gas Fireplace47INSTALLATIONOPTIONAL FAN INSTALLATIONImportant: 120 Volt AC power is needed for the fan switch and blower.
48Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONAn optional AC power adaptor may be installed as a constant power source for the SureFire system
Regency Bellavista™ B36XTE Gas Fireplace49INSTALLATIONGT REMOTE INSTALLATION6) Identify wires in the GT remote wiring harness. (see wiring diagra
Regency Bellavista™ B36XTE Gas Fireplace5SAFETY LABELThis is a copy of the label that accompanies each Bellavista™ B36XTE Direct Vent Gas Fireplace. W
50Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONOptional WALL SWITCH1) Run the supplied 10' of wire through the right or left side gas inl
Regency Bellavista™ B36XTE Gas Fireplace51INSTALLATIONGTM REMOTE INSTALLATION6) Identify wires in the GTM/GTMF remote wiring harness. (see wiring
52Regency Bellavista™ B36XTE Gas FireplaceINSTALLATION10) Install the stepper motor in the same location the hi/lo knob was removed from - with
Regency Bellavista™ B36XTE Gas Fireplace53INSTALLATIONGTMF REMOTE INSTALLATION6) Disconnect wire harness, ground wire and spark wire from DFC.1) Shut
54Regency Bellavista™ B36XTE Gas FireplaceINSTALLATION17) Install the heat shield onto the fan control module - then install onto the velcro
Regency Bellavista™ B36XTE Gas Fireplace55INSTALLATION584 Proflame GT Series Feature Sheet (X) Indicates Included FeatureNote 1 ~ Profl ame Flame Modul
56Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONAERATION ADJUSTMENTThe burner aeration is factory set but may need adjusting due to either the l
Regency Bellavista™ B36XTE Gas Fireplace57INSTALLATIONProflame SystemConfiguration886 GTMFWire DiagramPROFLAME SYSTEM WIRING DIAGRAMCONFIGURATION: 886
58Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONImportant: 120 Volt AC power is required to operate the light. The receptacle box will be inst
Regency Bellavista™ B36XTE Gas Fireplace59INSTALLATION15) Install the halogen bulb supplied with the kit. Important: Use caution - do not to
6Regency Bellavista™ B36XTE Gas FireplaceREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional re
60Regency Bellavista™ B36XTE Gas FireplaceINSTALLATION18) Reinstall the logs.19) Reinstall glass door and bottom louver / full screen doors.20) Plu
Regency Bellavista™ B36XTE Gas Fireplace61INSTALLATIONFLUSH GLASS DOOR INSTALLATION1) Line up slots on fl ush glass door with tabs in fi rebox. Hook s
62Regency Bellavista™ B36XTE Gas FireplaceINSTALLATIONFinishingTrim TopFinishingTrim SideNOTE: Install the Finishing Trim prior to installing the Flu
Regency Bellavista™ B36XTE Gas Fireplace63INSTALLATIONFULL SCREEN ARCH DOOR AND FRAME INSTALLATIONDiagram 1Diagram 2Diagram 4Diagram 5cDiagram 3aDiagr
64Regency Bellavista™ B36XTE Gas Fireplace64OPERATING INSTRUCTIONSOPERATING INSTRUCTIONS1) Read and understand these instructions before operating th
Regency Bellavista™ B36XTE Gas Fireplace6565INSTALLATIONOPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONS918-628bsA) This appliance is equip
66Regency Bellavista™ B36XTE Gas FireplaceMAINTENANCEliner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of c
Regency Bellavista™ B36XTE Gas Fireplace67MAINTENANCEREMOVING VALVE10) Remove the 8 Phillips head screws securing the valve tray assembly in place (Sc
68Regency Bellavista™ B36XTE Gas FireplacePARTS LISTMAIN ASSEMBLY Part # Description 1) 576-084F Top Insulation P
Regency Bellavista™ B36XTE Gas Fireplace69PARTS LIST23FAN SWITCH ASSEMBLYFAN SWITCH ASSEMBLY22202134561378161714121011189151912MAIN ASSEMBLY
Regency Bellavista™ B36XTE Gas Fireplace7DIMENSIONSUNIT DIMENSIONS40-5/16” (1024mm)21”(533mm)33” (838mm)36” (914mm)35-1/4”(895mm)30-3/8” (762mm)1”(25.
70Regency Bellavista™ B36XTE Gas FireplacePARTS LISTBURNER ASSEMBLY Part # Description 1) 576-077 Rear L
Regency Bellavista™ B36XTE Gas Fireplace71WARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our i
Printed in CanadaRegency™, Bellavista™,Surefi re™, and AstroCap™ are trademarks of FPI Fireplace Products International Ltd.© Copyright 2011, FPI Firep
8Regency Bellavista™ B36XTE Gas FireplaceINSTALLATION9) Wear gloves and safety glasses for protection while doing required maintenance.10) Be aware o
Regency Bellavista™ B36XTE Gas Fireplace9INSTALLATIONThis includes:1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label 3