WARNING:
If the information in these instructions are not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-914
04/11/11
Owners &
Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
MODELS: B41XT-NG1
B41XT-LP1
www.regency- re.com
Regency Bellavista
B41XT
Gas Fireplace
Page view 0
1 2 3 4 5 6 ... 63 64

Summary of Contents

Page 1 - Gas Fireplace

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury

Page 2

10Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONCaution RequirementsThe top, back and sides of the fi replace are defi ned by standoffs. The metal

Page 3

Regency Bellavista™ B41XT Gas Fireplace11INSTALLATIONMANTEL CLEARANCESNote: Ensure the paint that is used on the mantel and the facing is "heat

Page 4 - TABLE OF CONTENTS

12Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONMANTEL LEG CLEARANCESNON-COMBUSTIBLE REQUIREMENTSMin. 13-1/2"(343mm)50-1/4"(1276mm)Non-

Page 5 - SAFETY LABEL

Regency Bellavista™ B41XT Gas Fireplace13INSTALLATIONFRAMING MNOQPRUVTOpening for gasconnection11" (279mm)dia. Hole throughwall Vent.Non-Combusti

Page 6 - REQUIREMENTS

14Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONFINISHINGNon-combustibleMaterialJ-style Trimor metal corner beadmay be used to finish theseedgesN

Page 7 - DIMENSIONS

Regency Bellavista™ B41XT Gas Fireplace15INSTALLATIONal - /4"UNIT ASSEMBLY PRIOR TO INSTALLATIONBEFORE YOU STARTThe Top Facing Support, the Side

Page 8

16Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONCONVERSION TO TOP VENTNote: This conversion must be done prior to the unit being placed in posit

Page 9 - INSTALLATIONINSTALLATION

Regency Bellavista™ B41XT Gas Fireplace17INSTALLATION7) From the outside top of the fi rebox - remove the intake cover plate by removing the 4 - 1/4&

Page 10 - INSTALLATION

18Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONVENT RESTRICTOR & BAFFLE INSTALLATIONNOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLE

Page 11

Regency Bellavista™ B41XT Gas Fireplace19INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTSMinimum Clearance RequirementsCanada1USA2A Clearance above

Page 12

2Regency Bellavista™ B41XT Gas FireplaceTo the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The Bella

Page 13

20Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONAdjustable Length 3”-10”-Galvanized N/A N/A 5DAL TC-5DLTAdjustable Length 3”-10”-Black N/A N/A 5D

Page 14

Regency Bellavista™ B41XT Gas Fireplace21INSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™Metal-Fab™Sure SealICC Excel DirectAttic Ins

Page 15

22Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONThe diagrams show all allowable combinations of vent runs with 5" x 8" venting using th

Page 16

Regency Bellavista™ B41XT Gas Fireplace23INSTALLATIONHORIZONTAL TERMINATIONSFLEX VENT 5" X 8" These venting systems, in combination with the

Page 17

24Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONRigid Pipe AdaptorPipe Length90 ElbowoHorizontalTerminationCapWall ThimbleVinyl SidingStandoff (O

Page 18

Regency Bellavista™ B41XT Gas Fireplace25INSTALLATIONHORIZONTAL TERMINATIONSASTROCAP XL & RIGID REAR VENT KITFOR CORNER INSTALLATIONSRIGID PIPE 5&

Page 19

26Regency Bellavista™ B41XT Gas FireplaceINSTALLATION1622001212661818447-1/2"(1207mm)MinimumHeightRequirement414881010 14 161818 20Vertical Heigh

Page 20

Regency Bellavista™ B41XT Gas Fireplace27INSTALLATIONRIGID PIPE VENTING SYSTEMSBASIC HORIZONTAL & VERTICAL TERMINATIONSRigid Pipe Vent Systems off

Page 21

28Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONHORIZONTAL TERMINATIONSTWO (2) 90O ELBOWS (RIGID PIPE 5" X 8")HH1VOption V H

Page 22

Regency Bellavista™ B41XT Gas Fireplace29INSTALLATIONVENTING ARRANGEMENTSFOR VERTICAL TERMINATIONSThe shaded area in the diagram shows all allowable c

Page 23

Regency Bellavista™ B41XT Gas Fireplace3MANUFACTURED MOBILE HOME REQUIREMENTSINFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALEThis Regency® p

Page 24

30Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONVH1HV1VERTICAL TERMINATIONS THREE (3) 90O ELBOWS (RIGID PIPE 5" X 8") Option

Page 25

Regency Bellavista™ B41XT Gas Fireplace31INSTALLATIONDiagram 7Diagram 57) Ensure that the pipe clearances to combustible materials are maintained (D

Page 26

32Regency Bellavista™ B41XT Gas FireplaceINSTALLATION1) Locate the unit in the framing, rough in the gas (preferably on the right side of the unit).

Page 27

Regency Bellavista™ B41XT Gas Fireplace33INSTALLATIONGAS LINE INSTALLATIONThe gas line is brought through the right side of the appliance. The gas val

Page 28

34Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONGAS PIPEPRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by closi

Page 29

Regency Bellavista™ B41XT Gas Fireplace35INSTALLATIONMust install one of the following: Brick Panels, Stainless Steel or Black Enamel Panels.Dangerous

Page 30

36Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONOPTIONAL STAINLESS STEEL / BLACK ENAMEL PANEL INSTALLATIONLEFTBACKTOPRIGHTNote: Panels must be i

Page 31

Regency Bellavista™ B41XT Gas Fireplace37INSTALLATION4) Remove 1 screw (see inset A), position right side panel in fi rebox - position panel clip in

Page 32

38Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONLOG SET INSTALLATIONInstallation of Brick or Stainless Steel / Black Enamel Panels must be comple

Page 33

Regency Bellavista™ B41XT Gas Fireplace39INSTALLATIONLocation of backtabs on BurnerTab on BurnerTab on BurnerBack of Log HBack of Log GNotch - Log H B

Page 34

4Regency Bellavista™ B41XT Gas FireplaceTABLE OF CONTENTSSAFETY LABELCopy of Safety Decal ...5REQUIR

Page 35

40Regency Bellavista™ B41XT Gas FireplaceINSTALLATION11) Position Log E on top of Log G - fi t Log E into the pin on Log G as shown below.12) Wit

Page 36

Regency Bellavista™ B41XT Gas Fireplace41INSTALLATION18) Place Log D on the base of the fi rebox in between burner grate posts 3 and 4.19) Test fi re t

Page 37

42Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONOptional WALL SWITCH1) Run the supplied 10' of wire through the right or left side gas inle

Page 38

Regency Bellavista™ B41XT Gas Fireplace43INSTALLATIONOPTIONAL FAN INSTALLATIONImportant: 120 Volt AC power is needed for the fan switch and blower. Th

Page 39

44Regency Bellavista™ B41XT Gas FireplaceINSTALLATION9) Slide the thermodisc/cover assembly onto the bracket clip on the left underside of the fi reb

Page 40

Regency Bellavista™ B41XT Gas Fireplace45INSTALLATIONWIRING DIAGRAMAERATION ADJUSTMENTLINE VOLTAGE WIRING TO RECEPTACLE IN UNITTO MAKE OUTLETS INDEPEN

Page 41

46Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONLockwasherFanground wireNut#8 Ground Lug(for mobile home)Star washerTo Thermocouple INPilotAssemb

Page 42

Regency Bellavista™ B41XT Gas Fireplace47INSTALLATION584 Proflame GT Series Feature Sheet (X) Indicates Included FeatureNote 1 ~ Profl ame Flame Modula

Page 43

48Regency Bellavista™ B41XT Gas FireplaceINSTALLATION1) Shut off electrical supply. 2) Remove Full Screen Door and bottom Louver if installed.3)

Page 44

Regency Bellavista™ B41XT Gas Fireplace49INSTALLATION13) Install each light assembly from the underside of the fl oor of the fi rebox. Secure

Page 45

Regency Bellavista™ B41XT Gas Fireplace5SAFETY LABELThis is a copy of the label that accompanies each Bellavista™ B41XT Direct Vent Gas Fireplace. We

Page 46

50Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONFLUSH GLASS DOOR INSTALLATIONFinishingTrim TopFinishingTrim SideNOTE: Install the Finishing Trim

Page 47 - Feature Sheet

Regency Bellavista™ B41XT Gas Fireplace51INSTALLATIONLOUVERS / FLUSH PANEL INSTALLATION1. To install the lower louver or  ush panel - line up the 2

Page 48

52Regency Bellavista™ B41XT Gas FireplaceINSTALLATIONFULL SCREEN ARCH DOOR AND FRAME INSTALLATIONDiagram 1Diagram 2Diagram 3Diagram 3aDiagram 2a1) Rem

Page 49

Regency Bellavista™ B41XT Gas Fireplace53INSTALLATION12) Fasten the hinges to the lower screen mesh panel with 3 screws each as shown below. 13) F

Page 50

54Regency Bellavista™ B41XT Gas FireplaceINSTALLATION14) To install the top panel - line up the 2 tabs on the panel with the corresponding bracket

Page 51

Regency Bellavista™ B41XT Gas Fireplace555555Regency Bellavista™ B41XT Gas Fireplace55OPERATING INSTRUCTIONSOPERATING INSTRUCTIONSOPERATING INSTRUCTIO

Page 52

56Regency Bellavista™ B41XT Gas Fireplace56OPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONSTO TURN OFF GAS APPLIANCEFOR YOUR SAFETY READ BEFO

Page 53

Regency Bellavista™ B41XT Gas Fireplace5757Regency Bellavista™ B41XT Gas FireplaceMAINTENANCEMAINTENANCEby having excessive lateral runs, too many elb

Page 54

58Regency Bellavista™ B41XT Gas FireplaceMAINTENANCE1) Shut off electrical supply. 2) Remove Full Screen Door and bottom Louver if installed.3)

Page 55 - OPERATING INSTRUCTIONS

Regency Bellavista™ B41XT Gas Fireplace59MAINTENANCEVALVE REPLACEMENT11) Remove the 14 screws securing the valve tray assembly in place (Diagram 7) an

Page 56

6Regency Bellavista™ B41XT Gas FireplaceREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional req

Page 57 - MAINTENANCE

60Regency Bellavista™ B41XT Gas FireplaceRegency Bellavista™ B41XT Gas Fireplace60PARTS LISTPARTS LISTMAIN ASSEMBLY Part # Description

Page 58

Regency Bellavista™ B41XT Gas Fireplace6160PARTS LISTSTBURNER ASSEMBLY11546810111297 Part # Description 1) 506-070

Page 59

62Regency Bellavista™ B41XT Gas FireplacePARTS LISTACCESSORIES154362 Part # Description 1) 506-946 3-Sided Finishi

Page 60 - PARTS LIST

Regency Bellavista™ B41XT Gas Fireplace63WARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our in

Page 61

Printed in CanadaRegency Bellavista is a trademark of FPI Fireplace Products International Ltd.© Copyright 2011, FPI Fireplace Products International

Page 62

Regency Bellavista™ B41XT Gas Fireplace7DIMENSIONSUNIT DIMENSIONS46-11/16” (1186mm)38-3/16” (970mm)41-11/16” (1059mm)43” (1092mm)35” (889mm)49-3/16” (

Page 63 - WARRANTY

8Regency Bellavista™ B41XT Gas FireplaceINSTALLATION10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for terminati

Page 64 - warranty online

Regency Bellavista™ B41XT Gas Fireplace99INSTALLATIONINSTALLATIONThis includes:1) Clocking the appliance to ensure the correct fi ring rate (rate note