WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury
10Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONCaution RequirementsThe top, back and sides of the fi replace are defi ned by standoffs. The metal en
Regency Horizon HZ54EPV Gas Fireplace11INSTALLATIONs NON-COMBUSTIBLE FACING BOARDIf fi nishing the wall above the unit with paint -the non-combustible
12Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONMANTEL CLEARANCESDue to the extreme heat this fi replace emits, the mantel clearances are critical.
Regency Horizon HZ54EPV Gas Fireplace13INSTALLATIONFRAMING & FINISHING6) Determine the total thickness of facing material (eg. hardiboard + cera
14Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONABCDEFGHIJKLNon-CombustibleFacingMetal Stud (Header)on edgeMetal Stud(Header)on edge(Located on the
Regency Horizon HZ54EPV Gas Fireplace15INSTALLATIONFRAMING WITH A NEGATIVE VENT RUN70” (1778mm)80” (2032mm)Framing width - offset to one side (left o
16Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONNAILING STRIPSThe nailing strips come attached to the unit. There is 1 plate on each side,1 on the
Regency Horizon HZ54EPV Gas Fireplace17INSTALLATIONVent restriction is required for certain venting installations, see the diagrams in the "Venti
18Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONGAS POWER VENT INSTALLATIONRIGID PIPE ONLYFirestop Spacer(included w/power vent kit)BX Cable(sold s
Regency Horizon HZ54EPV Gas Fireplace19INSTALLATIONAdjustable Length 3”-10”-Galvanized N/A 5DALAdjustable Length 3”-10”-Black N/A 5DALBAdjustable Leng
2Regency Horizon HZ54EPV Gas Fireplace2Regency Horizon HZ54EPV Gas FireplaceTo the New Owner:Congratulations! You are the owner of a state-of-the-art
20Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONDescriptionSimpsonDirect Vent Pro®Metal-Fab™Sure SealAttic Insulation Shield 12” 58DVA-IS N/A from
Regency Horizon HZ54EPV Gas Fireplace21INSTALLATION02464040810101212141416161818202022222424262628283030323234343636383888Horizontal (Feet)40610101212
22Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTSMinimum Clearance RequirementsCanada1USA2AClearance above gra
Regency Horizon HZ54EPV Gas Fireplace23INSTALLATION11-3/4”11-3/4”Determinethe correctheight WARNING:ELECTRICAL CONNECTIONS SHOULD ONLY BE CARRIED OUT
24Regency Horizon HZ54EPV Gas FireplaceINSTALLATION8 ) Reattach the plate to the inside of the Power Vent outer frame with 2 screws from step 3.9) F
Regency Horizon HZ54EPV Gas Fireplace25INSTALLATIONPIPE CONNECTION FROM TERMINAL TO UNIT16) Install cap over terminal with 4 screws.Note: Cap may
26Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONELECTRICAL INSTALLATIONNote: For ease of installation, the electrical installation must be comple
Regency Horizon HZ54EPV Gas Fireplace27INSTALLATIONof 14) Reverse steps 6-1 to complete installation.15) Plug in Power Vent Module to outlet locate
28Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONPOWER VENT WIRING DIAGRAM911-031(750mm)wire#911-032(3000mm)0.584.2230.584.907NCCWHITEBLACKGREENBLAC
Regency Horizon HZ54EPV Gas Fireplace29INSTALLATIONAERATION ADJUSTMENTThe burner aeration is factory set but may need adjusting due to either the loca
Regency Horizon HZ54EPV Gas Fireplace3Regency Horizon HZ54EPV Gas Fireplace3This appliance can only be used with the type of gas indicated on the rati
30Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas sup-ply piping system by closi
Regency Horizon HZ54EPV Gas Fireplace31INSTALLATIONVALVE COVER REMOVALThe valve cover will need to be removed to access the valve tray (see valve tray
32Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONLockwasherFanground wireNut#8 Ground Lug(for mobile home)Star washerOPTIONAL FAN WIRING DIAGRAM WIT
Regency Horizon HZ54EPV Gas Fireplace33INSTALLATION RECEIVER WALL SWITCH (Included with Unit)1) Run the supplied 10' of t
34Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONWALL MOUNT RECEIVER INSTALLATIONREQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS
Regency Horizon HZ54EPV Gas Fireplace35INSTALLATION584 Proflame GT Series Feature Sheet (X) Indicates Included FeatureNote 1 ~ Profl ame Flame Modulato
36Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONBATTERY INSTALLATION1) Install 4 - AA batteries into the receiver, ensure correct polarity.J-BoxRe
Regency Horizon HZ54EPV Gas Fireplace37INSTALLATIONGTM REMOTE INSTALLATIONDFBC = digital fi replace burner control1) Remove the faceplate and glass
38Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONGTMF REMOTE INSTALLATIONDFBC = digital fi replace burner control1) Remove the faceplate and glass d
Regency Horizon HZ54EPV Gas Fireplace39INSTALLATION11) Install the fan control module onto t the fl oor of the unit. Place it to the right of the rece
4Regency Horizon HZ54EPV Gas FireplaceTABLE OF CONTENTSSAFETY LABELCopy of Safety Decal ...5REQUIREM
40Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONOPTIONAL REFLECTIVE PANEL INSTALLATION1) Position the left side panel in place - top of panel in fi
Regency Horizon HZ54EPV Gas Fireplace41INSTALLATIONGLASS CRYSTALS OR OPTIONAL CERAMIC STONESINSTALLATION ON BURNERGlass Crystals shown on BurnerFor Un
42Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONWhite River Pebbles shown surrounding the BurnerNatural River Pebbles shown surrounding the BurnerT
Regency Horizon HZ54EPV Gas Fireplace43INSTALLATIONInstallation of Refl ective Panels must be completed before installing the log set.Read the instruct
44Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONDiagram 54) Install the glass crystals (see glass crystal installation section in this manual).Pi
Regency Horizon HZ54EPV Gas Fireplace45INSTALLATION8) Place logs C + D on logs A + B, as shown in diagram 10. Note: Logs should be oriented exactly
46Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONFACEPLATE &DOOR FRAME OVERLAY INSTALLATION1) Install the door frame overlay by hooking the top
Regency Horizon HZ54EPV Gas Fireplace47INSTALLATIONCompleted Faceplate & Door Frame Overlay InstallationIMPORTANT NOTETo ensure the gap between th
48Regency Horizon HZ54EPV Gas FireplaceINSTALLATIONOPTIONAL FAN INSTALLATION1) Turn the unit off and allow it to cool down to room temperature.2) Tu
Regency Horizon HZ54EPV Gas Fireplace49INSTALLATION12) Secure the fan to the fl oor of the unit with 2 screws. *See wiring diagram in manual.13) Atta
Regency Horizon HZ54EPV Gas Fireplace5SAFETY LABELThis is a copy of the label that accompanies each HZ54EPV-NG and HZ54EPV-LP Direct Vent Gas Fireplac
50Regency Horizon HZ54EPV Gas FireplaceINSTALLATION19) Attach the receiver to the unit with the velcro strip. Place the receiver in front of the grou
Regency Horizon HZ54EPV Gas Fireplace5151INSTALLATIONOPERATING INSTRUCTIONSOPERATING INSTRUCTIONS1) Read and understand these instructions before ope
52Regency Horizon HZ54EPV Gas Fireplace52OPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONS918-948A) This appliance is equipped with an ignit
Regency Horizon HZ54EPV Gas Fireplace53MAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the gas valve before cleaning. For relighting, refer to
54Regency Horizon HZ54EPV Gas FireplaceMAINTENANCE1) Turn the unit off and allow it to cool down to room temperature.2) Turn off the gas supply to t
Regency Horizon HZ54EPV Gas Fireplace55MAINTENANCE1) Turn the unit off and allow it to cool down to room temperature.2) Turn off the gas supply to t
56Regency Horizon HZ54EPV Gas FireplaceMAINTENANCE1) Loosen 6 screws that secure the burner extenders. on burner tray, located behind the burner
Regency Horizon HZ54EPV Gas Fireplace57PARTS LISTMAIN ASSEMBLY23461578 Part # Description
58Regency Horizon HZ54EPV Gas FireplacePARTS LIST Part # Description 30) 476-907 Refl ective Stainless Steel Panels
Regency Horizon HZ54EPV Gas Fireplace59WARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our inte
6Regency Horizon HZ54EPV Gas FireplaceREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional requi
Printed in CanadaRegency Horizon and SureFire™ are trademarks of FPI Fireplace Products International Ltd.© Copyright 201133, FPI Fireplace Products I
Regency Horizon HZ54EPV Gas Fireplace7DIMENSIONS59” (1499mm)52-5/8” (1337mm)48-1/2” (1232mm)20-1/2” (521mm)19-3/4” (502mm)10-5/8”(270mm)1-1/2”(38mm)31
8Regency Horizon HZ54EPV Gas FireplaceINSTALLATION10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination
Regency Horizon HZ54EPV Gas Fireplace9INSTALLATIONThis includes:1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label 41,5