FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4918-988WARNING: Improper installation, adjustment, alteration
10Regency® HZI234E Direct Vent Gas InsertINSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe FPI Direct Vent Gas Insert must be installed in acco
Regency® HZI234E Direct Vent Gas Insert11INSTALLATION11) Due to high temperatures, the appliance should be located out of high traffi c areas and away
12Regency® HZI234E Direct Vent Gas InsertINSTALLATIONMINIMUM CLEARANCES TO COMBUSTIBLES Side Walls A 8" (203 mm)* Cei
Regency® HZI234E Direct Vent Gas Insert13INSTALLATIONTHE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLI
14Regency® HZI234E Direct Vent Gas InsertINSTALLATIONCONVERTING FROM 3" & 3" VENTING TO 3" & 2"1) Remove the top plate fr
Regency® HZI234E Direct Vent Gas Insert15INSTALLATIONGAS INSERT AERATION SYSTEMThe burner aeration is factory set but may need adjusting due to either
16Regency® HZI234E Direct Vent Gas InsertINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas sup-ply piping system by clo
Regency® HZI234E Direct Vent Gas Insert17INSTALLATIONTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERIF IN DOUBT DO NOT DO THIS CONVERSION !!Eac
18Regency® HZI234E Direct Vent Gas InsertINSTALLATION8) Remove the burner by removing 3 screws.9) Slide burner forward and lift up and out.16) Rein
Regency® HZI234E Direct Vent Gas Insert19INSTALLATION3) Attach the label “This unit has been converted to LPG” near or on top of the serial # decal.4
2Regency® HZI234E Direct Vent Gas InsertREGENCY GAS FIREPLACE INSERTTO THE NEW OWNERCongratulations! You are the owner of a state-of-the-art Gas Inse
20Regency® HZI234E Direct Vent Gas InsertINSTALLATIONGLASS CRYSTALS OR OPTIONAL CERAMIC STONESINSTALLATION ON BURNERGlass Crystals shown on BurnerFor
Regency® HZI234E Direct Vent Gas Insert21INSTALLATIONOPTIONAL PEBBLE / CRYSTAL INSTALLATIONFOR FIREBOX BASENatural River Pebbles shown surrounding the
22Regency® HZI234E Direct Vent Gas InsertINSTALLATIONREFLECTIVE PANEL INSTALLATION1) Remove the faceplate and glass door if already installed - see
Regency® HZI234E Direct Vent Gas Insert23INSTALLATIONGLASS DOOR REMOVAL / INSTALLATIONOPTIONAL SCREEN DOOR REMOVAL / INSTALLATION1) Remove the glass
24Regency® HZI234E Direct Vent Gas InsertINSTALLATIONLOW PROFILE FACEPLATE INSTALLATION(3 AND 4 SIDED)1) Install 4 screws on sides of unit - in locat
Regency® HZI234E Direct Vent Gas Insert25INSTALLATION11) Hook the front faceplate over the installed backing plate.12) Install the bottom louver by
26Regency® HZI234E Direct Vent Gas InsertINSTALLATIONCONTOUR & CONTEMPORARY FACEPLATEFaceplate Contents List:1 Faceplate (Contour or Contemporary
Regency® HZI234E Direct Vent Gas Insert27INSTALLATION7) Secure the loose wires into the wire clips above and to the bottom left of the battery pack a
28Regency® HZI234E Direct Vent Gas InsertINSTALLATIONDiagram 1113) Re-install the remote receiver bracket (reverse step 10).14) Close the left side fa
Regency® HZI234E Direct Vent Gas Insert29INSTALLATIONOPTIONAL BACKING PLATE3) Attach the top piece of the backing plate to the faceplate using 5 scre
Regency® HZI234E Direct Vent Gas Insert33TABLE OF CONTENTSSAFETY LABELCopy of safety decal...4REQUI
30Regency® HZI234E Direct Vent Gas InsertINSTALLATIONAttach Left & Right Backing Plate to Faceplate7) Align the screw holes on the left and right
Regency® HZI234E Direct Vent Gas Insert31INSTALLATIONOPTIONAL HEARTH TRIM-CONTOUR/STANDARD FACEPLATE1) Open the left and right side faceplate panels.
32Regency® HZI234E Direct Vent Gas InsertINSTALLATIONOPTIONAL HEARTH TRIM - LOW PROFILE FACEPLATE1) Align the screw holes on the hearth trim with the
Regency® HZI234E Direct Vent Gas Insert33INSTALLATIONPROFLAME REMOTE CONTROL RECEIVER INSTALLATION1) Remove faceplate if installed.2) From the rig
34Regency® HZI234E Direct Vent Gas InsertINSTALLATION6) Connect the wire harness to the back of the remote receiver; Place wire clip holder on the
Regency® HZI234E Direct Vent Gas Insert35INSTALLATIONCAUTIONDo not wire millivolt Thermostat wiresto 120V wire.Thermostat Wire TableRecommended Maximu
36Regency® HZI234E Direct Vent Gas InsertINSTALLATIONWIRING DIAGRAMThis heater does not require a 120V A.C. supply for operation. In case of a power f
Regency® HZI234E Direct Vent Gas Insert37INSTALLATIONAn optional AC power adaptor may be installed as a constant power source for the SureFire system.
38Regency® HZI234E Direct Vent Gas InsertINSTALLATIONFAN WIRING DIAGRAMCAUTION: Label all wires prior to disconnection when servicing controls. Wiring
Regency® HZI234E Direct Vent Gas Insert3939INSTALLATIONOPERATING INSTRUCTIONSOPERATING INSTRUCTIONS1) Read and understand these instructions before o
4Regency® HZI234E Direct Vent Gas Insert4SAFETY LABELSAFETY LABELThis is a copy of the labels that accompany each HZI234E Gas Insert. We have printed
40Regency® HZI234E Direct Vent Gas Insert40OPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONS918-628bA) This appliance is equipped with an ig
Regency® HZI234E Direct Vent Gas Insert41MAINTENANCE2) Remove the Termination Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or ot
42Regency® HZI234E Direct Vent Gas InsertMAINTENANCEFAN REPLACEMENT1) Unplug the power source.2) Open the left and right side faceplate panels.3) R
Regency® HZI234E Direct Vent Gas Insert43MAINTENANCEGround WireFan Cover Plate Removal13) Remove 13 screws to remove the fan access plate.14) Lift
44Regency® HZI234E Direct Vent Gas InsertMAINTENANCE1) Shut off gas supply to unit and unplug the power source by disconnecting the batteries.2) Ope
Regency® HZI234E Direct Vent Gas Insert45PARTS LIST1 536-016 Door Frame2 536-517/P Fan Assembly3 536-532 Flue adaptor Assy4 536-539 Door Frame Assy5 5
46Regency® HZI234E Direct Vent Gas InsertPARTS LIST3 AND 4 SIDED LOW PROFILE FACEPLATE ASSEMBLY Part # Description 1 566-924 3 sid
Regency® HZI234E Direct Vent Gas Insert47PARTS LISTFACEPLATE ASSEMBLY Part # Description
48Regency® HZI234E Direct Vent Gas InsertPARTS LISTBACKING PLATE & HEARTH TRIM ASSEMBLY Part # Description 53
Regency® HZI234E Direct Vent Gas Insert49NOTES
Regency® HZI234E Direct Vent Gas Insert5REQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional req
50Regency® HZI234E Direct Vent Gas InsertNOTES
Regency® HZI234E Direct Vent Gas Insert51WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our int
Printed in CanadaRegency and Horizon are trademarks of FPI Fireplace Products International Ltd.© Copyright 2011, FPI Fireplace Products International
6Regency® HZI234E Direct Vent Gas InsertDIMENSIONS20"510mm2918"739mm3278"836mm21532mm2278"581mm1"3"26mm[76mm]16"428
Regency® HZI234E Direct Vent Gas Insert7DIMENSIONSDIMENSIONS W/ LOW PROFILE 4 SIDED FACEPLATE20"510mm2918"739mm3278"836mm3014"770m
8Regency® HZI234E Direct Vent Gas InsertDIMENSIONS60°Contour FaceplateEIContemporary Faceplate27-3/4” (705mm)27-1/2” (699mm)19-1/2” (495mm)13” (330mm)
Regency® HZI234E Direct Vent Gas Insert9INSTALLATIONCLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. CHILDREN AND