FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4
918-667a
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury, property damage, or loss
of life. Refer to this manual. For assistance or additional
information consult an authorized installer, service agency
or the gas supplier.
FOR YOUR SAFETY:
Do not store or use gasoline or other ammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized
installer, service agency or the gas supplier.
FOR YOUR SAFETY:
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
11/12/13
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
L234 Gas Insert
Owners & Installation Manual
MODELS: L234-NG Natural Gas L234-LP Propane
Liberty L234 Product Video
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - L234 Gas Insert

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4918-667aWARNING: Improper installation, adjustment, alteratio

Page 2 - REGENCY GAS FIREPLACE INSERT

10Regency® L234 Direct Vent Gas InsertINSTALLATIONMINIMUM CLEARANCES TO COMBUSTIBLES Side Walls A 8" (203 mm)* Ceilin

Page 3 - TABLE OF CONTENTS

Regency® L234 Direct Vent Gas Insert11INSTALLATIONTHE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANC

Page 4 - SAFETY LABEL

12Regency® L234 Direct Vent Gas InsertINSTALLATIONCONVERTING FROM 3" & 3" VENTING TO 3" & 2"1) Remove the top plate from

Page 5 - REQUIREMENTS

Regency® L234 Direct Vent Gas Insert13INSTALLATIONGAS CONNECTION GAS CONNECTION WARNING:Only persons licensed to work with gas piping maymake the nece

Page 6 - DIMENSIONS

14Regency® L234 Direct Vent Gas InsertINSTALLATIONGAS INSERT AERATION ADJUSTMENTThe burner aeration is factory set but may need adjusting due to eithe

Page 7

Regency® L234 Direct Vent Gas Insert15INSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by closing

Page 8

16Regency® L234 Direct Vent Gas InsertINSTALLATIONCONVERSION KIT #536-969 FROM NG TO LPLP Conversion Kit Contains:Qty. Part # Description1 9

Page 9

Regency® L234 Direct Vent Gas Insert17INSTALLATION9) Remove burner orifi ce with a 1/2" wrench and discard.10) Install the new LP burner orifi ce

Page 10 - INSTALLATION

18Regency® L234 Direct Vent Gas InsertINSTALLATIONOPTIONAL BRICK PANEL INSTALLATION1) Carefully remove the brick panels from the box and unwrap them

Page 11

Regency® L234 Direct Vent Gas Insert19INSTALLATIONSCREEN DOOR INSTALL/ REMOVAL GLASS DOOR INSTALL/ REMOVAL1) Remove the glass door. a) Pull off th

Page 12

2Regency® L234 Direct Vent Gas InsertREGENCY GAS FIREPLACE INSERTTO THE NEW OWNERCongratulations! You are the owner of a state-of-the-art Gas Insert

Page 13

20Regency® L234 Direct Vent Gas InsertINSTALLATIONCONTOUR OR CONTEMPORARY FACEPLATE Faceplate Contents List:1 Faceplate (Contour or Contemporary)1

Page 14

Regency® L234 Direct Vent Gas Insert21INSTALLATION7) From the right side of the unit connect the black electrode wire to the DC Sparker as shown in d

Page 15

22Regency® L234 Direct Vent Gas InsertINSTALLATION13) Tuck the wires completely into the sleeve and place the supplied cable tie to the end of it as s

Page 16

Regency® L234 Direct Vent Gas Insert23INSTALLATIONOPTIONAL BACKING PLATE3) Attach the top piece of the backing plate to the faceplate using 5 screws

Page 17

24Regency® L234 Direct Vent Gas InsertINSTALLATIONAttach Left & Right Backing Plate to Faceplate7) Align the screw holes on the left and right si

Page 18

Regency® L234 Direct Vent Gas Insert25INSTALLATIONOPTIONAL HEARTH TRIM- CONTOUR/ CONTEMPORARY FACEPLATE1) Open the left and right side faceplate pane

Page 19

26Regency® L234 Direct Vent Gas InsertINSTALLATIONOPTIONAL HEARTH TRIM - LOW PROFILE FACEPLATE1) Align the screw holes on the hearth trim with the sc

Page 20

Regency® L234 Direct Vent Gas Insert27INSTALLATIONLOG SET INSTALLATIONLog kit (Part # 536-930) contains the following pieces: a) 2-711 Rear Log b) 2-

Page 21

28Regency® L234 Direct Vent Gas InsertINSTALLATION5) Fit the left side of log 2-713 into the pin on log 2-714 and rest the right side of the log on t

Page 22

Regency® L234 Direct Vent Gas Insert29INSTALLATION7) Place embers on the right side of the burner as shown. 8) Fit log 2-716 into the pin on log 2

Page 23

Regency® L234 Direct Vent Gas Insert33TABLE OF CONTENTSSAFETY LABELSafety Label...4REQ

Page 24

30Regency® L234 Direct Vent Gas InsertINSTALLATIONCompleted Log Set Installation2-7112-7162-715 2-7122-7132-714

Page 25

Regency® L234 Direct Vent Gas Insert31INSTALLATIONWIRING DIAGRAMSThis heater does not require a 120V A.C. supply for operation. However, a 120V A.C.

Page 26

32Regency® L234 Direct Vent Gas InsertINSTALLATIONUse of FPI Remote Control Kit #910-399 or #910-368 is approved for this unit. Use of other systems m

Page 27

Regency® L234 Direct Vent Gas Insert3333INSTALLATIONOPERATING INSTRUCTIONSIMPORTANT: Gas on/off knob cannot be turned from "PILOT" to "

Page 28

34Regency® L234 Direct Vent Gas Insert34OPERATING INSTRUCTIONSCOPY OF LIGHTING INSTRUCTION PLATE AUTOMATIC CONVECTION FAN OPERATIONThe fan operates a

Page 29

Regency® L234 Direct Vent Gas Insert35MAINTENANCE2) Remove the Termination Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other

Page 30

36Regency® L234 Direct Vent Gas InsertMAINTENANCEFAN REPLACEMENT1) Unplug the power source.2) Open the left and right side faceplate panels.3) Remo

Page 31

Regency® L234 Direct Vent Gas Insert37MAINTENANCE11) Unplug the fan connector wires.12) Remove the 2 screws that hold the fan bracket in place.13) Re

Page 32

38Regency® L234 Direct Vent Gas InsertMAINTENANCEVALVE REPLACEMENT1) Open the left and right side faceplate panels.2) Remove the bottom louver by pu

Page 33 - OPERATING INSTRUCTIONS

Regency® L234 Direct Vent Gas Insert39MAINTENANCE13) Remove the rear log tray by undoing the 3 screws.Rear Log Tray Removed14) Remove the 12 screws th

Page 34

4Regency® L234 Direct Vent Gas InsertSAFETY LABELThis is a copy of the labels that accompany each L234 Gas Insert. We have printed a copy of the conte

Page 35 - MAINTENANCE

40Regency® L234 Direct Vent Gas InsertPARTS LISTMAIN ASSEMBLY Part # Description Part # Description

Page 36

Regency® L234 Direct Vent Gas Insert41PARTS LISTFACEPLATE ASSEMBLY Part # Description

Page 37

42Regency® L234 Direct Vent Gas InsertPARTS LISTBACKING PLATE & HEARTH TRIM ASSEMBLY Part # Description 536-9

Page 38

Regency® L234 Direct Vent Gas Insert43WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our intern

Page 39

Printed in CanadaRegency and Liberty are trademarks of FPI Fireplace Products International Ltd. © Copyright 2013, FPI Fireplace Products Internationa

Page 40 - PARTS LIST

Regency® L234 Direct Vent Gas Insert5REQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional requir

Page 41

6Regency® L234 Direct Vent Gas InsertDIMENSIONS

Page 42

Regency® L234 Direct Vent Gas Insert7INSTALLATIONCLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. CHILDREN AND AD

Page 43 - WARRANTY

8Regency® L234 Direct Vent Gas InsertINSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe FPI Direct Vent Gas Insert must be installed in accordan

Page 44 - warranty online

Regency® L234 Direct Vent Gas Insert9INSTALLATION11) Due to high temperatures, the appliance should be located out of high traffi c areas and away from