FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-849aMODELS: P33E-NG4 Natural Gas P33E-LP4 Propane1
10Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONCaution RequirementsThe top, back and sides of the fi replace are defi ned by stan
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace11INSTALLATIONCOMBUSTIBLE MANTELSBecause of the extreme heat this fi replace emits, the mantel
12Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONMANTEL LEG CLEARANCES WITH CONTEMPORARY FACEPLATECombustible mantel leg clearanc
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace13INSTALLATION3) For exterior walls, insulate the enclosure to the same degree as the rest of
14Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONGHIIMJLKPQON10" (254mm)dia. Hole throughwall Vent.Opening for gasconnection
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace15INSTALLATIONNote: When constructing the framed opening, please ensure there is access to in
16Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONThe Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace17INSTALLATIONEXTERIOR VENT TERMINATION LOCATIONSMinimum Clearance RequirementsCanada1USA2A Cl
18Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONWherever necessary due to external location of cap, the AstroCap can be replaced
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace19INSTALLATIONTermination CapWall Thimble 2 pieces(10" (254mm) Outer Diameter)2”x4”or2”x6
2Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceTo the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by F
20Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONRIGID PIPE VENTING SYSTEMSHorizontal or Vertical TerminationsThe minimum compone
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace21INSTALLATION4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufactur
22Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Amer
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace23INSTALLATION• Vent must be supported at offsets.• Firestops are required at each fl oor l
24Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONThe P33E-4 is approved for a maximum 40 ft. straight vertical, with rigid pipe v
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace25INSTALLATIONRIGID PIPE VENTING ARRANGEMENTS Horizontal TerminationsREGENCY® DIRECT VENT SYS
26Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONHorizontal Venting with Two (2) 90o ElbowsHorizontal Venting with Two (2) 90o El
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace27INSTALLATIONHorizontal Venting with Three (3) 90o ElbowsVertical Venting with Two (2) 90o El
28Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONVertical Venting with Three (3) 90o ElbowsVertical Venting with Three (3) 90o El
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace29INSTALLATIONFlex LinerExhaustFlueA maximumof two certifiedjoiner kitsmay be usedper length.#
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace3INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALEThis Regency® product has been test
30Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONVENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace31INSTALLATIONRiser VentTerminationMin. 6-1/4"*(159mm)Diagram 3UNIT INSTALLATION WITH HOR
32Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONGAS LINE INSTALLATIONThe gas line is brought through the right side of the appli
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace33INSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply pipi
34Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONEach Kit contains one LPG Conversion Kit LPG Conversion Kit Contains:Qty. Part #
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace35INSTALLATION16) Unscrew the pilot orifi ce with the Allen key and replace with the LPG pilot
36Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONNote: The logs must not be in the unit.3) Insert the back brick panel by carefu
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace37INSTALLATIONDiagram 1Diagram 3STANDARD FLUSH DOORThe standard fl ush door comes with a black
38Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATION6) Identify wires in the GT remote wiring harness. (see wiring diagram.)7)
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace39INSTALLATIONGTM REMOTE INSTALLATION6) Identify wires in the GTM/GTMF remote wiring harness
4Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace4TABLE OF CONTENTSFlush Louvers ...
40Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATION10) Install the stepper motor in the same location the hi/lo knob was remo
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace41INSTALLATIONGTMF REMOTE INSTALLATION6) Disconnect wire harness, ground wire and spark wire
42Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATION17) Install the heat shield onto the fan control module - then install
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace43INSTALLATIONOPTIONAL BAY DOORThe Bay louvers MUST be usedwith the Bay glass option.The optio
44Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATION6) Open the bottom louver. Pull the Burner ON/OFF control box from inside the b
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace45INSTALLATIONFULL SCREEN DOORS1) Before beginning the installation, remove the Glass Door f
46Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATION6) Place the Bottom Frame near the hinges, and fl ip down the hinges from the Bo
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace47INSTALLATIONContemporary Faceplate Derating Kit Contains:Qty. Part # Description1 904-434
48Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONCONTROL MOUNTING PLATE INSTALLATION(FOR P33-4 UNIT WITH FACEPLATE ONLY)1) Remov
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace49INSTALLATION1) Install the control shield with 2 #8 - 1/2" Phillips screws to the bott
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace5SAFETY LABELSAFETY LABELThis is a copy of the label that accompanies each P33E-4 Zero Clearan
50Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONDiagram 7Diagram 8Diagram 9Image of P33-4 with Faceplate Image of P33S with Fa
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace51INSTALLATIONOptional WALL SWITCH1) Run the supplied 10' of wire through the right or l
52Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONWIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. I
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace53INSTALLATIONINSTALLING THE OPTIONAL FAN120 Volt AC power is needed for the fan switch and bl
54Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace54OPERATING INSTRUCTIONSCOPY OF THE LIGHTING PLATE INSTRUCTIONS918-628bA) This appliance i
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace55551) Press and release on ON/OFF button once on the remote control or ON/OFF switch.2) Aft
56Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceMAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the gas valve before cleaning. For re
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace57MAINTENANCEGLASS GASKET If the glass gasket requires replacement use 5/8" fl at glass ga
58Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceMAINTENANCEREMOVING VALVE1) Shut off the gas supply.2) Remove the louvers (and bay door if
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace59PARTS LISTMAIN ASSEMBLY Part # Description Part # Description
6Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the followi
60Regency® P33E-4 Zero Clearance Direct Vent Gas FireplacePARTS LIST
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace61PARTS LISTLO57795983858687686768668258605355BURNER & LOG ASSEMBLY Part Description
62Regency® P33E-4 Zero Clearance Direct Vent Gas FireplacePARTS LISTFLUSH FRONT & LOUVERS Part # Description Part #
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace63PARTS LIST Part # Description 1) 434-516 Faceplate
64Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceNOTES
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace65NOTES
66Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceNOTES
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace67WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In
Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace7INSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe P33E-NG4 or P33E-LP4 Direct Vent Fi
8Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONDUCT SYSTEM OPTIONKit #946-556The HeatWave Air Duct Kit increases the effectiven
Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace9INSTALLATIONUNIT DIMENSIONS WITH CONTEMPORARY FACEPLATE33"(838mm)33"(838mm)23"
Comments to this Manuals