FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-522c10/28/13P36D-1 Zero ClearanceDirect Vent Gas Firep
10Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe P36D-NG1 or P36D-LP1 Direct Vent Fi
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace11INSTALLATIONDiagram 1This includes:1) Clocking the appliance to ensure the correct fi ring r
12Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONThe HeatWave Duct Kit and the Heat Release Kit have different clearance and fram
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace13INSTALLATIONClearances for Flush Front& Full Screen DoorsREGENCY® CLEARANCESTRIPOLI ARCH
14Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONDrywall12" Mantel7 1/2" Mantel3 1/2"MantelMantel Clearances withF
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace15INSTALLATIONREGENCY® SERIES COMBUSTIBLE MANTEL CLEARANCESBecause of the extreme heat this fi
16Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONREGENCY® MANTEL LEG CLEARANCESCombustible mantel leg clearances as per diagram:M
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace17INSTALLATIONFraming Dimensions A B C D 36-1/4" 37-1/4" 17-3/8&qu
18Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONWhen installing the optional Tripoli Arch Door, a non-combustible material 12&q
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace19INSTALLATIONSideNailing Strips"C" Screw Position:For a facing material depth of 1-
2Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceTo the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by R
20Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONEXTERIOR VENT TERMINATION LOCATIONSMinimum Clearance RequirementsCanada1USA2ACle
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace21INSTALLATIONVENTINGDIRECT VENT SYSTEM (FLEX) HORIZONTAL TERMINATIONS ONLYThese venting syst
22Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATION4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufactur
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace23INSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Amer
24Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONRigid Pipe AdaptorPipe LengthVerticalTerminationCapStorm CollarFlashingCeiling F
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace25INSTALLATIONVENTING ARRANGEMENTS HORIZONTAL TERMINATIONRIGID PIPE AND FPI DIRECT VENT SYSTE
26Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATION• Vent must be supported at offsets.• Firestops are required at each fl oor l
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace27INSTALLATIONThe P36D-1 is approved for a 40 ft. straight vertical, with rigid pipe vent syst
28Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONHORIZONTAL VENTING WITH TWO (2) 90O ELBOWSHORIZONTAL VENTING WITH THREE (3) 90O
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace29INSTALLATIONVH1HV1VERTICAL VENTING WITH TWO (2) 90O ELBOWSVERTICAL VENTING WITH THREE (3) 90
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace3INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALEThis REGENCY® product has been test
30Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONVERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEMTHE APPLIANCE MUST NOT BE CONNECT
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace31INSTALLATIONVENTING ARRANGEMENT - VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY F
32Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONDiagram 46) The arrow on the vent cap should be pointing up. Insure that the 1-
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace33INSTALLATIONDiagram 3Diagram 5Diagram 1Diagram 2NOTE: For best results and optimum performa
34Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATION4) Separate the 2 halves of the wall thimble and securely fasten the one with t
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace35INSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply pipi
36Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERIF IN DOUBT DO NOT DO THIS
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace37INSTALLATIONInstallation of the DC Sparker:16) Verify that if the conversion is from NG to
38Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATION27) Run the other end of the ground wire and DC spark generator wires through t
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace39INSTALLATION 1) Undo the bottom 2 door latches and open and remove glass door. Remove logs
4Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceTABLE OF CONTENTSVertical Termination ...26
40Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONNotchBracketBracket02-5102-7502-513) Place the Log 02-75 on the rear log suppor
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace41INSTALLATIONLOG SET INSTALLATION Rear Bracket02-5502-7502-537) Place the bottom left fron
42Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONLog IndentationPhoto shows rear grate tab. Log 02-51 was removed to show the pos
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace43INSTALLATIONPlace embers in these 3 locations on the burner tray.02-5002-5502-7502-5302-5102
44Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONDiagram 3Use the hook to pull the spring out until you can put the hook into the
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace45INSTALLATION14 GA.16 GA.18 GA.20 GA.22 GA.50 Ft.32 Ft.20 Ft.12 Ft.9 Ft.Recommended Maximum L
46Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONWIRING DIAGRAMS Caution: Ensure that the wires do not touch any hot surface
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace47INSTALLATIONFor PROPANE Units and Units Equipped with DC Spark Boxes**For installation of th
48Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONOPTIONAL FAN INSTALLATION120 Volt AC power is needed for the fan switch and blow
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace4949INSTALLATIONOPERATING INSTRUCTIONSIMPORTANT Gas on/off knob cannot be turned from "PI
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace55TABLE OF CONTENTSOPERATING INSTRUCTIONSOperating Instructions ...
50Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace50OPERATING INSTRUCTIONSMAINTENANCE INSTRUCTIONS1) Always turn off the gas valve before cle
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace51MAINTENANCENote: Never operate the appliance without the glass properly secured in place.6)
52Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceMAINTENANCE11) Undo the pilot tube from the valve with a 7/16" wrench.12) Undo the qui
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace5353INSTALLATIONREGENCY® OPTIONSFLUSH LOUVERS 1) Install the top louver by sliding the two
54Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace54REGENCY® OPTIONSFULL SCREEN DOOR INSTALLATION1) Before beginning the installation, rem
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace5555INSTALLATIONREGENCY® OPTIONS3) Install the hinges to the hinge brackets on the left and r
56Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace56REGENCY® OPTIONSWhen installing the optional Tripoli Screen Door Series, a non-combustible
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace5757INSTALLATIONREGENCY® OPTIONSNote: The facing material has to go on after the unit is set.
58Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace58REGENCY® OPTIONSNote: The Nailing Strips can be adjusted, depending on the facmaterial (as
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace59PARTS LIST323133BRICK PANEL SETDOORS & LOUVERS PLEASEREFER SEPARATE SECTION2202354318791
6Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceSAFETY LABELThis is a copy of the label that accompanies each P36D-1 Zero Clearance Direct Ve
60Regency® P36D-1 Zero Clearance Direct Vent Gas FireplacePARTS LISTBURNER ASSEMBLY & LOG SET Part # Description 52) 910-190 Piezo Igni
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace61PARTS LISTREGENCY® FLUSH FRONT ASSEMBLY Part # Description Part # Descri
62Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceNOTES
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace63WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In
Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace7REQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the followi
8Regency® P36D-1 Zero Clearance Direct Vent Gas FireplaceINSTALLATION36" (914mm)33"(838mm)36"(914mm)30-1/2"(775mm)37"(940mm)1
Regency® P36D-1 Zero Clearance Direct Vent Gas Fireplace9INSTALLATIONCLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANC