Regency FIREGENIE FG39-NG User Manual

Browse online or download User Manual for Tools Regency FIREGENIE FG39-NG. Regency FIREGENIE FG39-NG User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
05/26/06
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult an authorized installer, serv-
ice agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flamma-
ble vapours and liquids in the vicinity of this
or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Owners &
Installation
Manual
LISTINGS AND CODE APPROVALS
These gas appliances have been tested
in accordance with AS4553-2000, NZS
5262 and have been certified by the
Australian Gas Association for installation
and operation as described in these
Installation and Operating Instructions.
Your unit should be serviced
annually by an authorised service
person.
918-278a
Models: FG39-NG
FG39-LPG
Freestanding Gas Stove
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - Freestanding Gas Stove

05/26/06FOR YOUR SAFETYWhat to do if you smell gas:Do not try to light any appli-anceDo not touch any electricalswitch: do not use anyphone in you

Page 2 - UNIT SPECIFICATIONS

10Regency FG39 FireGenie Freestanding Gas StoveINSTALLATIONDV STOVE HORIZONTAL FLUE KIT (#946-112) INSTALLATIONMinimum Installation Height:FG39:

Page 3 - TABLE OF CONTENTS

Regency FG39 FireGenie Freestanding Gas Stove11INSTALLATIONd) Cut the 2 ft. (.6m) section of rigid pipeto length. Ensure that the pipe lengthwhen cut

Page 4 - SAFETY LABEL

12Regency FG39 FireGenie Freestanding Gas StovePipe LengthRound SupportBox/Wall Thimble(Part # 940)RoundSupport Box/Wall Thimble(Part # 940)VerticalTe

Page 5

Regency FG39 FireGenie Freestanding Gas Stove13Diagram 5Note: If installing termination on a siding cov-ered wall, a vinyl siding standoff or furring

Page 6

14Regency FG39 FireGenie Freestanding Gas StoveDiagram 11: The upper half of the flashing isinstalled under the roofing material and notnaile

Page 7

Regency FG39 FireGenie Freestanding Gas Stove15INSTALLATIONOffset ChartDiagram 13Notes:a) For multistorey vertical installations, aCeiling Fire stop

Page 8

16Regency FG39 FireGenie Freestanding Gas StoveINSTALLATIONGAS CONNECTIONThe gas line should be rigid pipe. Copper mayalso be used if approved by A

Page 9

Regency FG39 FireGenie Freestanding Gas Stove17INSTALLATIONConversion Kit for NG to LPG Model #736-969THIS CONVERSION MUST BE DONE BY A QUALI

Page 10 - INSTALLATION

18Regency FG39 FireGenie Freestanding Gas StoveInstaller Notice:These instructions must be left withthe appliance.Minimum pressure: Remove one of

Page 11

Regency FG39 FireGenie Freestanding Gas Stove19LOG SETINSTALLATIONRead the instructions below carefullyand refer to the diagrams. If logs

Page 12

2Regency FG39 FireGenie Freestanding Gas StoveTo the New Owner:Congratulations! You are the owner of a state-of-the-art Regency Room Sealed Gas Stove

Page 13

20Regency FG39 FireGenie Freestanding Gas StoveNotchE)02-45BracketA)02-65The bottom right edge of Log G)02-48 mustsit snugly against the bracke

Page 14

Regency FG39 FireGenie Freestanding Gas Stove21INSTALLATIONDiagram 1FRONT DOORINSTALLATION(packaged separately)1) Open the two side panels.2) Slide

Page 15

22Regency FG39 FireGenie Freestanding Gas StoveWIRINGCAUTION: Label all wires prior todisconnection when servicing con-trols. Wiring errors can caus

Page 16

Regency FG39 FireGenie Freestanding Gas Stove23OPERATING INSTRUCTIONSFIRST FIREThe FIRST FIRE in your heater is part of the paintcuring process. To

Page 17

24Regency FG39 FireGenie Freestanding Gas StoveOPERATING INSTRUCTIONSNORMAL OPERATINGSOUNDS OFGAS APPLIANCESIt is possible that you will hear

Page 18

Regency FG39 FireGenie Freestanding Gas Stove25COPY OF THE LIGHTING PLATE INSTRUCTIONSWARNING:DO NOT SPRAY AEROSOLS IN THE VICINITY OFTHIS APPLIA

Page 19

26Regency FG39 FireGenie Freestanding Gas StoveMAINTENANCECAUTION: ANY SAFETY SCREENOR GUARD REMOVED FOR SERV-ICING AN APPLIANCE MUST BEREPLACED PRIO

Page 20

Regency FG39 FireGenie Freestanding Gas Stove27Mitred Glass ReplacementRemoving Glass:1) Remove the door from the unit and place ona soft surface

Page 21

28Regency FG39 FireGenie Freestanding Gas StoveMAINTENANCEFAN MAINTENANCEIf your fan requires maintenance or replace-ment, access to the fan is

Page 22

Regency FG39 FireGenie Freestanding Gas Stove29MAINTENANCE4) Remove the two outside frame pieces byremoving two screws per side. See dia

Page 23 - OPERATING INSTRUCTIONS

Regency FG39 FireGenie Freestanding Gas Stove3TABLE OF CONTENTS Page PageOperating Inst

Page 24

30Regency FG39 FireGenie Freestanding Gas StoveFG37 FG38 FG39 PG33 PG36 HG35 PG121/PG131910-915910-082910-088910-089910-

Page 25

Regency FG39 FireGenie Freestanding Gas Stove31PARTS LIST25) * Flex Pipe (3" ID)26) * Clamp for Flex Pipe29) * Air Deflector30) 730-044 Rear Pan

Page 26 - MAINTENANCE

32Regency FG39 FireGenie Freestanding Gas StoveFG39 BURNER & LOG ASSEMBLY57) * Switch Plate730-574/P Valve Assembly - NG60) 910-378 Valve - S.I.T

Page 27

Regency FG39 FireGenie Freestanding Gas Stove33PARTS LISTFG39 DOOR ASSEMBLIES Part # Description730-924 Gold Mitred Door - Complete730-926

Page 28

34Regency FG39 FireGenie Freestanding Gas Stove_______________________________________________________________________________________________________

Page 29

Regency FG39 FireGenie Freestanding Gas Stove35WARRANTYExclusions:This limited Lifetime Warranty does not extend to or includepaint, door or glass gas

Page 30 - PARTS LIST

Printed in Canada© Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.

Page 31

4Regency FG39 FireGenie Freestanding Gas StoveSAFETY LABELThis is a copy of the label that accompanieseach REGENCY FG39 Freestanding Gas Stove

Page 32

Regency FG39 FireGenie Freestanding Gas Stove5IMPORTANT:SAVE THESEINSTRUCTIONSThe REGENCY Room Sealed Freestanding GasStove must be installed in acco

Page 33

6Regency FG39 FireGenie Freestanding Gas StoveINSTALLATION2) If required, adjusting the primary air toensure that the flame does not carbon. Fir

Page 34

Regency FG39 FireGenie Freestanding Gas Stove7LOUVERINSTALLATION1) Attach the top & bottom louvres to theside stove panel using 2 screws perside.I

Page 35 - WARRANTY

8Regency FG39 FireGenie Freestanding Gas StoveINSTALLATIONEXTERIOR FLUE TERMINATION LOCATIONSMinimum clearances required for balanced flue terminal

Page 36 - Printed in Canada

Regency FG39 FireGenie Freestanding Gas Stove9INSTALLATIONFLUEING ARRANGEMENTSVertical Terminations UsingDura-Flue Fluing System forResidential Manuf

Comments to this Manuals

No comments