Regency Freestanding Gas Stove F39-LPG User Manual

Browse online or download User Manual for Tools Regency Freestanding Gas Stove F39-LPG. Regency Freestanding Gas Stove F39-LPG User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 31
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
05/18/06
Freestanding Gas Stove
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fi re
department.
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorized installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other fl am-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Owners &
Installation
Manual
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AG 103, NZS 5262 and
have been certifi ed by the Australian Gas
Association for installation and operation
as described in these Installation and
Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
918-535
Models: F39-NG
F39-LPG
Page view 0
1 2 3 4 5 6 ... 30 31

Summary of Contents

Page 1 - Freestanding Gas Stove

05/18/06Freestanding Gas StoveFOR YOUR SAFETYWhat to do if you smell gas: Do not try to light any appli-ance Do not touch any electri-cal switch: do

Page 2 - UNIT SPECIFICATIONS

10Regency® F39 Room Sealed Freestanding Gas StoveINSTALLATIONDV STOVE HORIZONTAL FLUE KIT (# 946-112) INSTALLATIONMinimum Installation Height:F39: 59-

Page 3 - TABLE OF CONTENTS

Regency® F39 Room Sealed Freestanding Gas Stove11INSTALLATIONwhen cut will seat onto both the starter collar and the 90o elbow. Crimped section of ri

Page 4 - SAFETY LABEL

12Regency® F39 Room Sealed Freestanding Gas StovePipe LengthRound SupportBox/Wall Thimble(Part # 940)RoundSupport Box/Wall Thimble(Part # 940)Vertical

Page 5

Regency® F39 Room Sealed Freestanding Gas Stove13Diagram 5Note: If installing termination on a siding covered wall, a vinyl siding standoff or fur-ri

Page 6

14Regency® F39 Room Sealed Freestanding Gas StoveDiagram 11: The upper half of the fl ashing is installed under the roofi ng material and not nailed dow

Page 7

Regency® F39 Room Sealed Freestanding Gas Stove15GAS CONNECTIONThe gas connection is a 3/8" NPT 90o elbow. The gas line can be rigid pipe or to m

Page 8

16Regency® F39 Room Sealed Freestanding Gas StoveBurner Inlet Orifi ce Sizes: NG LPG Burner #32 #50 2.95mm

Page 9

Regency® F39 Room Sealed Freestanding Gas Stove17INSTALLATIONCONVERSION KIT #731-968 FROM NG TO LPGTHIS CONVERSION MUST BE DONE BY AN AUTHORIZED GAS F

Page 10 - INSTALLATION

18Regency® F39 Room Sealed Freestanding Gas StoveLOG SET INSTALLATIONRead the instructions below carefully and refer to the diagrams. If logs are bro

Page 11

Regency® F39 Room Sealed Freestanding Gas Stove19NotchE)02-45BracketA)02-65The bottom right edge of Log G)02-48 must sit snugly against the bracketSid

Page 12

2Regency® F39 Room Sealed Freestanding Gas StoveTo the New Owner:Congratulations! You are the owner of a state-of-the-art Regency® Room Sealed Gas St

Page 13

20Regency® F39 Room Sealed Freestanding Gas StoveOPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired. Connect the wires as per the

Page 14

Regency® F39 Room Sealed Freestanding Gas Stove21WIRINGCAUTION: Label all wires prior to dis-connection when servicing controls. Wiring errors can c

Page 15

22Regency® F39 Room Sealed Freestanding Gas StoveADJUSTING FLAME HEIGHT Your heater has an adjustable fl ame to tailor the look and heat output to your

Page 16

Regency® F39 Room Sealed Freestanding Gas Stove23NORMAL OPERATING SOUNDS OF GAS APPLIANCESIt is possible that you will hear some sounds from your gas

Page 17

24Regency® F39 Room Sealed Freestanding Gas StoveMAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the valve before cleaning. For relighting, ref

Page 18

Regency® F39 Room Sealed Freestanding Gas Stove25Mitred Glass ReplacementRemoving Glass1) Remove the door from the unit and place on a soft surface t

Page 19

26Regency® F39 Room Sealed Freestanding Gas StoveMAINTENANCEFAN MAINTENANCEIf your fan requires maintenance or replacement, access to the fan is throu

Page 20

Regency® F39 Room Sealed Freestanding Gas Stove27REMOVING VALVE2) Undo the six screws holding the control panel in place.3) Disconnect all wires fro

Page 21

28Regency® F39 Room Sealed Freestanding Gas StovePARTS LIST31) 630-021 Fan Access Panel32) 730-028 Firebox Baffl e33) 630-520 False Top Assembly36)

Page 22 - OPERATING INSTRUCTIONS

Regency® F39 Room Sealed Freestanding Gas Stove29F39 BURNER & LOG ASSEMBLY52) 910-190 Piezo Ignitor & Nut54) 910-373 Knob - Pilot Valve Ex

Page 23

Regency® F39 Room Sealed Freestanding Gas Stove3TABLE OF CONTENTSOPERATING INSTRUCTIONSOperating Instructions ...

Page 24 - MAINTENANCE

30Regency® F39 Room Sealed Freestanding Gas StovePARTS LISTF39 DOOR ASSEMBLIES Part # Description 730-924

Page 25

Regency® F39 Room Sealed Freestanding Gas Stove31WARRANTYExclusions:This limited Lifetime Warranty does not extend to or include paint, door or glass

Page 26

4Regency® F39 Room Sealed Freestanding Gas StoveSAFETY LABELThis is a copy of the label that accompanies each REGENCY F39 Room Sealed Freestanding Gas

Page 27

Regency® F39 Room Sealed Freestanding Gas Stove5IMPORTANTSAVE THESE INSTRUCTIONSThe REGENCY Room Sealed Freestanding Gas Stove must be installed in ac

Page 28 - PARTS LIST

6Regency® F39 Room Sealed Freestanding Gas StoveINSTALLATIONBefore leaving this unit with the customer, the installer must ensure that the appliance i

Page 29

Regency® F39 Room Sealed Freestanding Gas Stove7LOUVER INSTALLATION1) Attach the top & bottom louvres to the side stove panel using 2 screws per

Page 30

8Regency® F39 Room Sealed Freestanding Gas StoveINSTALLATIONEXTERIOR FLUE TERMINATION LOCATIONSMinimum clearances required for balanced fl ue terminals

Page 31 - WARRANTY

Regency® F39 Room Sealed Freestanding Gas Stove9INSTALLATIONFLUING ARRANGEMENTSVertical Terminations Using Dura-Flue Fluing System for Residential Man

Comments to this Manuals

No comments