Regency PTO60-NG Installation Manual

Browse online or download Installation Manual for Fireplaces Regency PTO60-NG. Regency PTO60-NG Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-844b
MODELS: U32SE-NG5
U32SE-LP5
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to
this manual. For assistance or additional information consult
an authorized installer, service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
U32SE Sunrise
Gas Insert
12/14/11
Owners &
Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.regency- re.com
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - 32SE Sunrise

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-844b MODELS: U32SE-NG5 U32SE-L

Page 2

10U32SE-5 FPI Direct Vent Gas InsertINSTALLATIONGKLABCABDECMANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS1) Ensure that structural members are not

Page 3

U32SE-5 FPI Direct Vent Gas Insert11INSTALLATIONVENTINGTHE APPLIANCE MUST NOT BE CONNECTED TO ACHIMNEY FLUE SERVING A SEPARATE SOLID FUELBURNING APPLI

Page 4 - TABLE OF CONTENTS

12U32SE-5 FPI Direct Vent Gas InsertINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by closing i

Page 5 - SAFETY LABEL

U32SE-5 FPI Direct Vent Gas Insert13INSTALLATIONCONVERSION KIT # 425-972 FROM NG TO LP U32SE-5 using SIT 886 NOVA Gas ValveEach Kit contains one LPG

Page 6 - REQUIREMENTS

14U32SE-5 FPI Direct Vent Gas InsertINSTALLATION16) Unscrew the pilot orifi ce with the Allen key and replace with the LPG pilot orifi ce in the kit an

Page 7 - DIMENSIONS

U32SE-5 FPI Direct Vent Gas Insert15INSTALLATIONFINAL CHECKBefore leaving this unit with the customer, the installer must ensure that the appliance is

Page 8

16U32SE-5 FPI Direct Vent Gas InsertINSTALLATIONWIRING DIAGRAMSThis heater does not require a 120V A.C. supply for operation. In case of a power failu

Page 9

U32SE-5 FPI Direct Vent Gas Insert17INSTALLATIONAn optional AC power adaptor may be installed as a constant power source for the SureFire system. IMPO

Page 10 - INSTALLATION

18U32SE-5 FPI Direct Vent Gas InsertINSTALLATION6) Identify wires in the GT remote wiring harness. (See attached wiring diagram for details. )7)

Page 11

U32SE-5 FPI Direct Vent Gas Insert19INSTALLATION4) Remove DFC (digital fi rebox control box) from the fl oor of the unit.5) Disconnect wire harness, g

Page 12

2U32SE-5 FPI Direct Vent Gas InsertTO THE NEW OWNERCongratulations! You are the owner of a state-of-the-art Gas Insert by Regency®.The U32SE Gas Inse

Page 13

20U32SE-5 FPI Direct Vent Gas InsertINSTALLATION12) Plug receiver wire harness wires from the receiver into the DFC box.13) Reinstall the DFC box o

Page 14

U32SE-5 FPI Direct Vent Gas Insert21INSTALLATIONGLASS CRYSTAL OR OPTIONAL CERAMIC STONESINSTALLATION ON BURNERGlass Crystals shown on BurnerFor Units

Page 15

22U32SE-5 FPI Direct Vent Gas InsertINSTALLATIONNatural River Pebbles shown surrounding the a Horizon BurnerThere are 2 optional packages to choose fr

Page 16

U32SE-5 FPI Direct Vent Gas Insert23INSTALLATIONOPTIONAL REFLECTIVE PANEL INSTALLATIONBefore installation, panels must be handled and cleaned as per i

Page 17

24U32SE-5 FPI Direct Vent Gas InsertINSTALLATIONInstallation of Black Enamel or Stainless Steel Panels7) Slide the right side stainless steel / black

Page 18

U32SE-5 FPI Direct Vent Gas Insert25INSTALLATIONDiagram 3Diagram 2 To remove the fl ush door, reverse the above steps.IMPORTANT NOTE: The chain must re

Page 19

26U32SE-5 FPI Direct Vent Gas InsertINSTALLATIONFACEPLATE AND DOOR FRAME INSTALLATION3) Position faceplate on unit lining up screw holes on faceplate

Page 20

U32SE-5 FPI Direct Vent Gas Insert27INSTALLATION7) Install the door frame by hooking the top fl ange over the top of the glass door.9) Run supplied 1

Page 21

28U32SE-5 FPI Direct Vent Gas InsertINSTALLATIONThe Hearth Trim is an option that can be used to fi nish off the installation when the bottom of the fi

Page 22

U32SE-5 FPI Direct Vent Gas Insert29INSTALLATION3) Connect the female ends of the ON/OFF switch - to the ON/OFF switch in the control box.1) Attach

Page 23

U32SE-5 FPI Direct Vent Gas Insert3This FPI Mobile/Manufactured Home listed appliance comes equipped with a dedicated #8 ground lug to which an 18 gau

Page 24

30U32SE-5 FPI Direct Vent Gas InsertINSTALLATION9) Install the top door pressure retainer, required.10) Take the outer faceplate, line up the openin

Page 25

U32SE-5 FPI Direct Vent Gas Insert31INSTALLATIONLOW PROFILE - OPTIONAL HEARTH TRIM INSTALLATIONHearth Trim is an option that can be used to fi nish off

Page 26

32U32SE-5 FPI Direct Vent Gas Insert32OPERATING INSTRUCTIONSDuring the fi rst few fi res, a white fi lm may develop on the glass front as part of the c

Page 27

Regency Gas Fireplace33OPERATING INSTRUCTIONSMAINTENANCE INSTRUCTIONS1) Always turn the gas valve to off before cleaning. For relighting, refer to l

Page 28

34U32SE-5 FPI Direct Vent Gas Insert34OPERATING INSTRUCTIONSCOPY OF LIGHTING INSTRUCTION PLATE918-628bsA) This appliance is equipped with an ignitio

Page 29

U32SE-5 FPI Direct Vent Gas Insert35MAINTENANCEGENERAL VENT MAINTENANCEConduct an inspection of the venting system semi-annually. Recommended areas to

Page 30

36U32SE-5 FPI Direct Vent Gas InsertMAINTENANCEFAN MAINTENANCEIf your fan requires maintenance or replacement, access to the fan is through the plate

Page 31

U32SE-5 FPI Direct Vent Gas Insert37MAINTENANCE8) Remove the base cover by lifting up from the back and manoeuvre out.Base Cover13) Remove the fan ac

Page 32 - OPERATING INSTRUCTIONS

38U32SE-5 FPI Direct Vent Gas InsertMAINTENANCE20) Disconnect green ground wire from power cord.REPLACING THE FAN Scrape off the old gasket from t

Page 33

U32SE-5 FPI Direct Vent Gas Insert39MAINTENANCEVALVE ASSEMBLY REPLACEMENT1) Turn the unit off and allow it to cool down to room temperature.2) Turn

Page 34

4U32SE-5 FPI Direct Vent Gas Insert4TABLE OF CONTENTSOptional Hearth Trim Installation ...28Low Profi le faceplate instal

Page 35 - Flame Sensor

40U32SE-5 FPI Direct Vent Gas InsertMAINTENANCE10) Remove the valve tray by undoing the 12 screws as shown below.11) Slightly lift out valve tray.12)

Page 36 - MAINTENANCE

U32SE-5 FPI Direct Vent Gas Insert41PARTS LIST1) 420-122 Fan Access Panel2) 420-142 Gasket - Fan Access Panel 422-518/P Fan Assembly:3) 910-215/P

Page 37

42U32SE-5 FPI Direct Vent Gas InsertPARTS LISTBURNER ASSEMBLY Part # Description43968213519) 911-006 Pilot Assembly - NG

Page 38

U32SE-5 FPI Direct Vent Gas Insert43PARTS LISTFACEPLATE AND DOOR FRAME Part Description3121) 425-512 Door Bottom Assembly2) 425-513 F

Page 39

44U32SE-5 FPI Direct Vent Gas InsertPARTS LISTLOW PROFILE FACEPLATE Part # Description1) * Backplate Assembly2) *

Page 40

U32SE-5 FPI Direct Vent Gas Insert45NOTES

Page 41 - PARTS LIST

46U32SE-5 FPI Direct Vent Gas InsertNOTES

Page 42

U32SE-5 FPI Direct Vent Gas Insert47WARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our interna

Page 43

48U32SE-5 FPI Direct Vent Gas InsertPrinted in CanadaFPI, Regency®, Sunrise™ and SureFire™ are trademarks of FPI Fireplace Products International Ltd.

Page 44

U32SE-5 FPI Direct Vent Gas Insert5SAFETY LABELThis is a copy of the label that accompanies each U32SE-5 Gas Insert. We have printed a copy of the con

Page 45

6U32SE-5 FPI Direct Vent Gas Insert6REQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional require

Page 46

U32SE-5 FPI Direct Vent Gas Insert77DIMENSIONS40-3/4” (1036mm)21-15/32” (545mm)27-7/8” (708mm)14-5/8” (371mm)35-15/16” (912mm)23-15/16” (607mm)Low Pro

Page 47 - WARRANTY

8U32SE-5 FPI Direct Vent Gas Insert4) See general construction and assembly instructions. This appliance may only be installed in a vented, noncombus

Page 48

U32SE-5 FPI Direct Vent Gas Insert9INSTALLATIONSPECIFICATIONSAt pressures over 1/2 psig, the pipe to the unit must be disconnected.Gas Input Capacity:

Comments to this Manuals