WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-759
Regency Bellavista
B36X
Gas Fireplace
02/05/09
Owners &
Installation Manual
www.regency- re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
MODEL: B36X
Medium DV Gas Fireplace
Page view 0
1 2 3 4 5 6 ... 63 64

Summary of Contents

Page 1 - Gas Fireplace

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury o

Page 2 - To the New Owner:

10Regency Bellavista™ B36X Gas FireplaceINSTALLATIONMANTEL CLEARANCESNote: Ensure the paint that is used on the mantel and the facing is "heat

Page 3 - TABLE OF CONTENTS

11Regency Bellavista™ B36X Gas FireplaceINSTALLATIONFRAMING MNOQPRUVTOpening for gasconnection11" (279mm)dia. Hole throughwall Vent.Top HeaderDry

Page 4 - SAFETY LABEL

12Regency Bellavista™ B36X Gas FireplaceINSTALLATIONFINISHINGDiagram 2Diagram 1IMPORTANT FINISHING DETAIL NOTE: Before placing unit into fi

Page 5 - REQUIREMENTS

13Regency Bellavista™ B36X Gas FireplaceBEFORE YOU STARTThe Top Facing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must

Page 6 - DIMENSIONS

14Regency Bellavista™ B36X Gas FireplaceINSTALLATIONTOP FLUE COLLAR INSTALLATIONNote: This conversion must be done prior to the unit being placed in

Page 7

15Regency Bellavista™ B36X Gas FireplaceINSTALLATION6) From the outside top of the fi rebox, remove the intake collar plate by removing the 4 - 1/4&q

Page 8

16Regency Bellavista™ B36X Gas FireplaceEXTERIOR VENT TERMINATION REQUIREMENTSINSTALLATIONMinimum Clearance RequirementsCanada1USA2A Clearance above

Page 9

17Regency Bellavista™ B36X Gas FireplaceINSTALLATIONAPPROVED VENTING CONFIGURATIONSHORIZONTAL & VERTICAL TERMINATIONS

Page 10 - INSTALLATION

18Regency Bellavista™ B36X Gas FireplaceAPPROVED VENTING CONFIGURATIONSHORIZONTAL & VERTICAL TERMINATIONSINSTALLATIONVertical Venting Configurati

Page 11

19Regency Bellavista™ B36X Gas FireplaceINSTALLATIONRIGID PIPE CROSS REFERENCE CHART4" X 6-5/8" (MUST USE VENT REDUCER # 946-606 AND RIGID P

Page 12

2Regency Bellavista™ B36X Gas FireplaceTo the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The Bella

Page 13

20Regency Bellavista™ B36X Gas FireplaceINSTALLATION

Page 14

21Regency Bellavista™ B36X Gas FireplaceINSTALLATIONRIGID PIPE CROSS REFERENCE CHART5" X 8" Components from different Manufacturers may not

Page 15

22Regency Bellavista™ B36X Gas FireplaceINSTALLATION

Page 16

23Regency Bellavista™ B36X Gas FireplaceINSTALLATIONHORIZONTAL TERMINATIONSREGENCY® DIRECT VENT FLEX SYSTEM (5" X 8")These venting systems,

Page 17

24Regency Bellavista™ B36X Gas FireplaceINSTALLATIONRigid Pipe AdaptorPipe Length90 ElbowoHorizontalTerminationCapWall ThimbleVinyl SidingStandoff (O

Page 18

25Regency Bellavista™ B36X Gas FireplacePipe LengthVerticalTerminationCapStorm CollarFlashingCeiling FirestopRigid Pipe AdaptorPipeLengthPipe Length90

Page 19

26Regency Bellavista™ B36X Gas FireplaceINSTALLATIONRigid Pipe AdaptorPipe LengthAstrocapXLWall ThimbleVinyl SidingStandoff(Optional)45 elbow0Designe

Page 20

27Regency Bellavista™ B36X Gas FireplaceVENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS(MUST USE VENT REDUCER # 946-606 & RIGID PIPE ADAPTOR

Page 21

28Regency Bellavista™ B36X Gas FireplaceINSTALLATIONHORIZONTAL VENTING WITH TWO (2) 90O ELBOWS(RIGID PIPE 4" X 6 - 5/8")16220012126618449&q

Page 22

29Regency Bellavista™ B36X Gas FireplaceHORIZONTAL VENTING WITH THREE (3) 90O ELBOWS(RIGID PIPE 4" X 6 - 5/8")V1H1HVLengths do not include e

Page 23

3Regency Bellavista™ B36X Gas FireplaceTABLE OF CONTENTSSAFETY LABELCopy of Safety Decal ...4REQUIRE

Page 24

30Regency Bellavista™ B36X Gas FireplaceINSTALLATIONVERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEMTHE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY F

Page 25

31Regency Bellavista™ B36X Gas FireplaceVENTING ARRANGEMENT - VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL

Page 26

32Regency Bellavista™ B36X Gas FireplaceDiagram 7Diagram 57) Ensure that the pipe clearances to combustible materials are maintained (Diagram 5). I

Page 27

33Regency Bellavista™ B36X Gas Fireplaceon top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other

Page 28

34Regency Bellavista™ B36X Gas FireplaceGAS LINE INSTALLATIONThe gas line is brought through the right side of the appliance. The gas valve is situat

Page 29

35Regency Bellavista™ B36X Gas FireplaceINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by closi

Page 30

36Regency Bellavista™ B36X Gas FireplaceWIRING DIAGRAMAERATION ADJUSTMENTThe burner aeration is factory set but may need adjusting due to either the

Page 31

37Regency Bellavista™ B36X Gas FireplaceINSTALLATIONLockwasherFanground wireNut#8 Ground Lug(for mobile home)Star washerTo Thermocouple INPilotAssembl

Page 32

38Regency Bellavista™ B36X Gas FireplaceINSTALLATIONVENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATIONNOTE: THE VENT RESTRICTOR & BAFFLE

Page 33

39Regency Bellavista™ B36X Gas FireplaceINSTALLATIONCONVERSION KIT# 556-969 FROM NG TO LPfor B36X using SIT 820 NOVA Gas ValveTHIS CONVERSION MUST BE

Page 34 - Diagram 1

4Regency Bellavista™ B36X Gas FireplaceSAFETY LABELThis is a copy of the label that accompanies each Bellavista™ B36X Direct Vent Gas Fireplace. We h

Page 35

40Regency Bellavista™ B36X Gas FireplaceINSTALLATION18) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the re

Page 36

41Regency Bellavista™ B36X Gas FireplaceINSTALLATIONDC Sparker Battery Replacement23) Locate the Piezo Ignitor situated at the right side of the

Page 37

42Regency Bellavista™ B36X Gas FireplaceINSTALLATIONDangerous operating conditions may occur if the panels are broken.Handle with care. DO NOT FORCE

Page 38

43Regency Bellavista™ B36X Gas FireplaceINSTALLATIONOPTIONAL STAINLESS STEEL / BLACK ENAMEL PANEL INSTALLATION1) Remove the heat defl ector by removing

Page 39

44Regency Bellavista™ B36X Gas FireplaceINSTALLATION5) Repeat step 4 for left side panel.5) Repeat step 4 for left side panel.6) Reverse step 1.6) Re

Page 40

45Regency Bellavista™ B36X Gas FireplaceINSTALLATIONLOG SET INSTALLATIONInstallation of Brick Panels must be completed before installing the log set.R

Page 41

46Regency Bellavista™ B36X Gas FireplaceINSTALLATIONBFABFCAFBCD5th Grate Tab2nd Grate TabNotch in log BNotch in log F5) Place Log F on the front left

Page 42

47Regency Bellavista™ B36X Gas FireplaceINSTALLATIONEABCDFBAFCDELava RocksPlatinum EmbersNotch in log D9) Place the lava rocks on the front of the b

Page 43 - Diagram 3

48Regency Bellavista™ B36X Gas FireplaceWALL SWITCH(INCLUDED)1) Run the supplied 10' of wire through the right or left side gas inlet opening.

Page 44

49Regency Bellavista™ B36X Gas FireplaceINSTALLATIONNote: Regency Profl ame wall switches are white (not black as shown).

Page 45

5Regency Bellavista™ B36X Gas FireplaceREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional requ

Page 46

50Regency Bellavista™ B36X Gas FireplaceFAN INSTALLATIONINSTALLATIONImportant: 120 Volt AC power is needed for the fan switch and blower. The recep

Page 47

51Regency Bellavista™ B36X Gas FireplaceINSTALLATIONFLUSH GLASS DOOR INSTALLATION1) Line up slots on fl ush glass door with tabs in fi rebox. Hook slo

Page 48

52Regency Bellavista™ B36X Gas FireplaceINSTALLATIONFinishingTrim TopFinishingTrim SideNOTE: Install the Finishing Trim prior to installing the Flus

Page 49

53Regency Bellavista™ B36X Gas FireplaceINSTALLATIONFULL SCREEN ARCH DOOR AND FRAME INSTALLATIONDiagram 1Diagram 2Diagram 4Diagram 3aDiagram 3bDiagram

Page 50

54Regency Bellavista™ B36X Gas FireplaceOPERATING INSTRUCTIONS1) Read and understand these instructions before operating this appliance.2) Check to

Page 51

55Regency Bellavista™ B36X Gas FireplaceOPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONSOFFa

Page 52

56Regency Bellavista™ B36X Gas FireplaceMAINTENANCE2) Remove the Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign

Page 53

57Regency Bellavista™ B36X Gas FireplaceMAINTENANCEREMOVING VALVE10) Remove the 8 Phillips head screws securing the valve tray assembly in place (Diag

Page 54 - OPERATING INSTRUCTIONS

58Regency Bellavista™ B36X Gas FireplacePARTS LISTMAIN ASSEMBLY Part # Description 1) 556-524 Flue Coll

Page 55

59Regency Bellavista™ B36X Gas FireplacePARTS LISTMAIN ASSEMBLY21FAN SWITCH ASSEMBLYFAN SWITCH ASSEMBLY2018191234115614151210891671317HEAT WAVE DUCT K

Page 56 - MAINTENANCE

6Regency Bellavista™ B36X Gas FireplaceDIMENSIONSUNIT DIMENSIONS37-1/2” (953mm)21”(533mm)33” (838mm)36” (914mm)35-1/4”(895mm)30-3/8” (762mm)1”(25.4mm

Page 57

60Regency Bellavista™ B36X Gas FireplaceBURNER ASSEMBLY1243567910PARTS LIST Part # Description 1) 556-077

Page 58 - PARTS LIST

61Regency Bellavista™ B36X Gas FireplaceNOTES

Page 59

62Regency Bellavista™ B36X Gas FireplaceNOTES

Page 60

63Regency Bellavista™ B36X Gas FireplaceWARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our int

Page 61

64Regency Bellavista™ B36X Gas FireplaceInstaller: Please complete the following informationDealer Name & Address: ______________________________

Page 62

7Regency Bellavista™ B36X Gas Fireplace11) Under no circumstances should this appliance be modifi ed. Parts that have to be removed for servicing shou

Page 63 - WARRANTY

8Regency Bellavista™ B36X Gas FireplaceINSTALLATIONThis includes:1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) a

Page 64

9Regency Bellavista™ B36X Gas FireplaceINSTALLATIONCaution RequirementsThe top, back and sides of the fi replace are defi ned by standoffs. The metal en