WARNING:
If the information in these instructions are not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-671c
MODELS: E21-NG3 Natural Gas E21-LP3 Propane
E21 Gas Insert
01/17/12
Owners &
Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.regency- re.com
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - E21 Gas Insert

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury

Page 2 - CONGRATULATIONS!

10 Regency® E21-3 Gas Fireplace InsertINSTALLATIONCLEARANCES TO COMBUSTIBLESThe minimum clearance from the side of the appliance to a combustible side

Page 3

Regency® E21-3 Gas Fireplace Insert11INSTALLATIONHIGH ELEVATIONThis unit is approved in Canada for altitude 0 to 4500 ft. (CAN/CGA 2.17-M91) with the

Page 4 - TABLE OF CONTENTS

12 Regency® E21-3 Gas Fireplace InsertINSTALLATIONWIRING DIAGRAMSCAUTION: Label all wires prior to disconnection when servicing controls. Wiring err

Page 5 - SAFETY LABEL

Regency® E21-3 Gas Fireplace Insert13INSTALLATIONNote: Do not operate unit if fl ue connector is not fastened in original position.FLUE CONNECTOR INS

Page 6 - REQUIREMENTS

14 Regency® E21-3 Gas Fireplace InsertINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by closing

Page 7

Regency® E21-3 Gas Fireplace Insert15INSTALLATIONTEST FOR FLUE SPILLAGEA " spillage" test must be made before the installed unit is left wi

Page 8

16 Regency® E21-3 Gas Fireplace InsertINSTALLATIONLOG SET INSTALLATIONLog kit (Part # 533-930) contains the following pieces: a) 27-23 Back Center L

Page 9

Regency® E21-3 Gas Fireplace Insert17INSTALLATION6) Fit log 27-26 into the pins on the front right side of the burner.5) Rest the top of log 27-25

Page 10 - INSTALLATION

18 Regency® E21-3 Gas Fireplace InsertINSTALLATION8) Fit log 27-28 into the pin on the left side of the burner.9) Fit the left end of log 27-29 into

Page 11

Regency® E21-3 Gas Fireplace Insert19INSTALLATIONCompleted Log Set Installation27-2311) Place embers along the front of the burner as shown. Ensure

Page 12

2 Regency® E21-3 Gas Fireplace InsertCONGRATULATIONS!You are the owner of a state-of-the-art Gas Insert by:FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.Th

Page 13

20 Regency® E21-3 Gas Fireplace InsertINSTALLATIONDiagram 4Diagram 56) Connect the ON/OFF switch wires by taking the black and red wires with the fem

Page 14

Regency® E21-3 Gas Fireplace Insert21INSTALLATIONFLUSH GLASS1) Install the bottom glass trim onto the glass support.2) Slide the glass into the bot

Page 15

22 Regency® E21-3 Gas Fireplace InsertINSTALLATIONConversion Kit# 534-969 from NG to LPTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DO

Page 16

Regency® E21-3 Gas Fireplace Insert23INSTALLATION17) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o

Page 17

24 Regency® E21-3 Gas Fireplace InsertINSTALLATIONInstaller Notice:These instructions must be left with the appliance.37) Check for gas leaks.38) Ch

Page 18

Regency® E21-3 Gas Fireplace Insert25INSTALLATIONFULL SCREEN DOORS1) Hold the full screen door up against the unit in order to make the following wi

Page 19

26 Regency® E21-3 Gas Fireplace InsertINSTALLATION6) Place Bottom Frame near hinge. Flip hinge over Bottom Frame and secure with 3 screws each.Bottom

Page 20

Regency® E21-3 Gas Fireplace Insert27INSTALLATION1) Attach the inner faceplate panel to the insert body using 4 screws in the locations shown below.

Page 21

28 Regency® E21-3 Gas Fireplace InsertINSTALLATIONDiagram 10Diagram 9Outer faceplateInner faceplatepanel pinsDiagram 117) Attach the bottom louver to

Page 22

Regency® E21-3 Gas Fireplace Insert29INSTALLATIONHearth Trim is an option that can be used to fi nish off the installation when the bottom of the fi re

Page 23

Regency® E21-3 Gas Fireplace Insert3INSTALLATION40-1/8"22-11/16"Low Profi le Faceplate Dimensions9-7/8”51* Standard size shown, custom size

Page 24

30 Regency® E21-3 Gas Fireplace InsertINSTALLATIONThermostat Wire TableCAUTIONDo not wire millivolt wall thermostat wiresto 120V wire.WALL SWITCH1) R

Page 25

Regency® E21-3 Gas Fireplace Insert3131INSTALLATIONOPERATING INSTRUCTIONSFINAL CHECKBefore leaving this unit with the customer, the installer must en

Page 26

32 Regency® E21-3 Gas Fireplace Insert32OPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONS 2) Wait fi ve (5) minutes to clear out any gas. If y

Page 27

Regency® E21-3 Gas Fireplace Insert33MAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn the gas valve to off before cleaning. For relighting, refer t

Page 28

34 Regency® E21-3 Gas Fireplace InsertMAINTENANCEREMOVING VALVE ASSEMBLY1) Disconnect the power.2) Shut off the gas.3) Remove top and bottom louve

Page 29

Regency® E21-3 Gas Fireplace Insert35PARTS LIST311012213335343636BRICK PANEL SET232745838383913174939MAIN ASSEMBLY Part # Description

Page 30

36 Regency® E21-3 Gas Fireplace InsertPARTS LISTBURNER ASSEMBLY & LOG SET Part # Description 533-574/P Valve

Page 31 - Pilot Adjust

Regency® E21-3 Gas Fireplace Insert37PARTS LIST FLUSH FRONT ASSEMBLY Part # Description Flush Door

Page 32 - OPERATING INSTRUCTIONS

38 Regency® E21-3 Gas Fireplace InsertWARRANTYFACEPLATE ASSEMBLY Part # Description 91) 910-330 Fan Spe

Page 33 - MAINTENANCE

Regency® E21-3 Gas Fireplace Insert39WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our intern

Page 34

4 Regency® E21-3 Gas Fireplace InsertTABLE OF CONTENTSSAFETY LABELSerial No. Decal ...4REQUIR

Page 35 - MAIN ASSEMBLY

Printed in CanadaRegency and Energy are trademarks of FPI Fireplace Products International Ltd.© Copyright 2012, FPI Fireplace Products International

Page 36 - BURNER ASSEMBLY & LOG SET

Regency® E21-3 Gas Fireplace Insert5SAFETY LABELThis is a copy of the label that accompanies each Regency® Gas Insert. We have printed a copy of the

Page 37 - FLUSH FRONT ASSEMBLY

6 Regency® E21-3 Gas Fireplace InsertREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional requir

Page 38 - WARRANTY

Regency® E21-3 Gas Fireplace Insert7INSTALLATIONBEFORE YOU STARTSafe installation and operation of this appliance requires common sense, however, we

Page 39

8 Regency® E21-3 Gas Fireplace InsertINSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe Regency® Gas Fireplace must be installed in accordance

Page 40 - warranty online

Regency® E21-3 Gas Fireplace Insert9INSTALLATION13-1/8” (333mm)Low prole faceplatePOLICY FOR SOLID FUEL BURNING & FACTORY BUILT FIREPLACESThe Re

Comments to this Manuals

No comments