Regency FP90 User Manual

Browse online or download User Manual for Stoves Regency FP90. Regency FP90 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
04/04/08
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Regency High Effi ciency EPA Certifi ed Fireplace
MODEL: FP90
FP90 Wood Fireplace
Owners &
Installation Manual
www.regency-fi re.com
918-426j
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - FP90 Wood Fireplace

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H404/04/08Tested by:Installer: Please complete the details on the

Page 2 - FPI FP90 Wood Fireplace2

FPI FP90 Wood Fireplace10INSTALLATIONFire StopFireStopStraightrunfor 8"(203mm)Hot Air DuctUnit projectsout flush withnon-combustible ma

Page 3 - TABLE OF CONTENTS

FPI FP90 Wood Fireplace 11INSTALLATIONVentilated Chase PanBEFORE YOU START Check your inventory list to be sure you have all the necessary parts supp

Page 4 - SAFETY LABEL

FPI FP90 Wood Fireplace12INSTALLATIONINSTALLATION MEASUREMENTS / FRAMING DETAILSINSTALLATION3"(76mm)STAND-OFF2x4FRAMINGFRONT OFUNIT ONLYCOMBUS

Page 5

FPI FP90 Wood Fireplace 13INSTALLATIONThere is also 1" unit base standoffs that are supplied with the unit. These are optional and are to be used

Page 6

FPI FP90 Wood Fireplace14INSTALLATION The performance of your unit is governed to a very large extent by the chimney system. Too short a chimney can

Page 7

FPI FP90 Wood Fireplace 15INSTALLATIONINSTALLING THE OUTSIDE AIR KITCombustion air is fed to the fi rebox through a connection on the rear lower left s

Page 8

FPI FP90 Wood Fireplace16INSTALLATIONPlan ViewJakel AX-2495 BlowerAngle ViewFan Transfer PlateRight ViewFront ViewFan 910-175 AX-3088910-903 910-516Gr

Page 9

FPI FP90 Wood Fireplace 17INSTALLATIONFlex VentDischargeVent GrilleDischarge Vent FrameConnectingCollarClampFlexVentInsulation Strips1) Remove the s

Page 10 - INSTALLATION

FPI FP90 Wood Fireplace18INSTALLATION... Metal Filler StripsMetal Filler StripsMIDDLE UPTOP UPLEFT SIDE UPRIGHT SIDE UPACBBNon-Combustible

Page 11

FPI FP90 Wood Fireplace 19INSTALLATIONNon-CombustibleMaterialMetalFillerStripsStand-off SpacersMetal Filler Strip60" (1524mm)CABB3/4" (19mm)

Page 12

FPI FP90 Wood Fireplace2Thank-you for purchasing a REGENCY FIREPLACE PRODUCT.The pride of workmanship that goes into each of our products will give yo

Page 13

FPI FP90 Wood Fireplace20INSTALLATIONSide PanelTopPanelInsulationTopBrickBottomVermiculiteMASONRY LINER / BRICKSInsulated refractory panels are includ

Page 14

FPI FP90 Wood Fireplace 21INSTALLATIONASH DRAWER KIT OPTION During constant use, ashes should be removed every few days. The Ash Drawer Kit option pro

Page 15

FPI FP90 Wood Fireplace22INSTALLATIONFAN INSTALLATIONNOTE: If optional Ashtray is installed, it must be removed before installing the fan. The rece

Page 16

FPI FP90 Wood Fireplace 23INSTALLATIONMASONRY COVER PLATE INSTALLATION5°INSTALL FOUR #8x1/2 SCREWSAT THESE LOCATIONS TO ATTACHTHE SURROUND TEMPLATE SI

Page 17

FPI FP90 Wood Fireplace24INSTALLATIONWITH THE SAME MOUNTING SCREWS AS THE SURROUND.INSTALL THE SURROUND TEMPLATE ONTO THE UNITWARNING: KEEP MASONRY MA

Page 18

FPI FP90 Wood Fireplace 25INSTALLATIONFINISHING TRIM KIT INSTALLATION2x4 FRAMINGLEFT SIDE TRIMRIGHT SIDE TRIM2x4 FRAMINGTOP TRIMSTEP #1NON-COMBUSTIBLE

Page 19

FPI FP90 Wood Fireplace26INSTALLATION2) Make sure the insulation under the top stand-off is up against the back of the top nailing strip.3) Fasten t

Page 20

FPI FP90 Wood Fireplace 27INSTALLATIONFIREPLACE SCREEN INSTALLATIONINSTALLING THE HANDLES ON THE SCREEN1) 1 or 2 handles can be installed on the scree

Page 21

FPI FP90 Wood Fireplace28INSTALLATIONREGENCY LOUVER INSTALLATIONInstalling the Top Louver1) Add two (2) screws (¼-20 X ½”) to the front of the fi repl

Page 22

FPI FP90 Wood Fireplace 29INSTALLATIONInstalling the Facing Guide1) Secure the left and right facing guides to the fi re-place with seven (7) screws (

Page 23

FPI FP90 Wood Fireplace 3TABLE OF CONTENTSSAFETY LABELSafety Label For FP90 ...4INSTALLATIONProduct D

Page 24

FPI FP90 Wood Fireplace30INSTALLATIONEXCALIBUR ACCENT KIT INSTALLATION3) Remove the 2 studs on the sides of the Hood. Insert the new studs through th

Page 25

FPI FP90 Wood Fireplace 31HEATWAVE KITHEATWAVE KIT (NOT EPA APPROVED)Diagram 1: Guide for possible air duct runs and locations. Keep duct length and n

Page 26

FPI FP90 Wood Fireplace32HEATWAVE KITHEATWAVE KIT (NOT EPA APPROVED)MINIMUM FRAMING CLEARANCES* Wall studs must be 16" on center for mounting fa

Page 27

FPI FP90 Wood Fireplace 33HEATWAVE KITHEATWAVE KIT (NOT EPA APPROVED)Diagram 44) Install the variable speed Wall Rheostat (with OFF setting) in a con

Page 28

FPI FP90 Wood Fireplace34OPERATIONOPERATING INSTRUCTIONSDraft ControlBoth the primary and air wash drafts are controlled by the control rod located be

Page 29

FPI FP90 Wood Fireplace 35MAINTENANCEPLATED FINISHESThe optional plated fi nishes on the louvers and surrounds requires little maintenance and needs o

Page 30

FPI FP90 Wood Fireplace36PARTS LISTPARTS LISTPARTS LIST- FIREBOX & BODY161213151442187653 Part # Description1) 001-127 Heat Deflector Top

Page 31 - INFORMATION

FPI FP90 Wood Fireplace 37PARTS LISTPARTS LISTPARTS LIST- BAFFLES, DOOR, OPTIONSSteel Handle - Left DoorSteel Handle - Right DoorAnchor Bracket - Left

Page 32 - MINIMUM FRAMING

FPI FP90 Wood Fireplace38NOTES________________________________________________________________________________________________________________________

Page 33 - WIRING DIAGRAM

FPI FP90 Wood Fireplace 39WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality A

Page 34 - OPERATING INSTRUCTIONS

FPI FP90 Wood Fireplace4SAFETY LABELSAFETY LABEL FOR FP90This is a copy of the label that accompanies each Regency Fireplace. It is located inside th

Page 35

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Page 36 - PARTS LIST

FPI FP90 Wood Fireplace 5INSTALLATIONINSTALLATIONPRODUCT DETAILSEPA Certifi ed Emissions : 3.72 g/hr Effi ciency (EPA) : 63% BTU/HR (EPA) :

Page 37

FPI FP90 Wood Fireplace6INSTALLATIONINSTALLATION6) Use solid fuel only. DO NOT use artifi cial logs containing petroleum products, chemical chimney cl

Page 38 - FPI FP90 Wood Fireplace38

FPI FP90 Wood Fireplace 7INSTALLATION38"43- 5/8"14- 5/8"13-3/8"28"9-5/8"25"15"4-3/4"50- 1/2" (1283m

Page 39 - WARRANTY

FPI FP90 Wood Fireplace8INSTALLATIONNo Combustibles on Face of Unit.Combustibles May Not Extend to Unit Face.Do not notch wallboard around standoffs.T

Page 40

FPI FP90 Wood Fireplace 9INSTALLATIONBuilding Structures Cannot Encroach on Chase50-3/4"(1289mm)44"(1118mm)INSTALLATION OF NAILING STRIPS1)