WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
® Do not try to light any appliance
® Do not touch any electrical switch:
do not use any phone in your
building.
® Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
® If you cannot reach your gas
supplier, call the fire department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4908-584a
MODELS: C34-NG2 Natural Gas C34-LP2 Propane
C34 Classic Direct Vent
Freestanding Gas Stove
Classic C34 model shown above features optional
gold plated door and gold legs.
01/09/06
Owners &
Installation Manual
www.regency-fire.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - Installation Manual

WARNING:If the information in these instructions are not followed exactly,a fire or explosion may result causing property damage,personal injury or lo

Page 2

10 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterINSTALLATIONEXTERIOR VENT TERMINAL LOCATIONS*As specified in CGA B149 or ANZI 223.1 Instal

Page 3 - TABLE OF CONTENTS

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 11946-506/P Vent Guard (Optional)640-530/P Riser Vent Terminal946-205 Vinyl Siding Shield fo

Page 4 - SAFETY LABEL

12 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterRIGID PIPE VENTING SYSTEMSHorizontal or Vertical TerminationsAlternateHorizontalTerminatio

Page 5

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 13VENTING ARRANGEMENTS -VERTICAL TERMINATIONSYSTEMS FOR RESIDENTIAL MAN-UFACTURED AND MOBILE

Page 6

14 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterHorizontal Venting with Two (2) 90o Elbows Option V H + H1 A) 4' Mi

Page 7

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 15INSTALLATIONDV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATIONDV STOVE HO

Page 8

16 Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heatere) Cut the 2 ft. or 4 ft. section of rigid pipeto length. Ensure that the pipe lengthwhen

Page 9

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 17INSTALLATIONDURA-VENTTERMINATION KITPlanning Your Dura-VentInstallationThere are two basic

Page 10 - INSTALLATION

18 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterYou will require the following Dura-Vent vent-ing components with your new CLASSIC Di-rect

Page 11

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 19INSTALLATIONDiagram4Below Grade InstallationIf the Snorkel Termination must be installedbe

Page 12

2 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterREGENCYClassic Direct Vent Freestanding Gas StoveThis Regency Mobile/Manufactured Home list

Page 13

20 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterDiagram 9penetrate theroof. Determine ifceiling joists,roof rafters orother framing willob

Page 14

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 21INSTALLATIONCATHEDRAL CEILINGSRound Support (RDS) & SquareSupport (SQS)If your home ha

Page 15

22 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterSupport extensions - Round(RDSE) or square (SQSE)Steep pitched cathedral ceilings may requ

Page 16

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 23INSTALLATION7) The connection between the appliance andthe Retro Connector may be complete

Page 17

24 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterSYSTEM DATA(For 0 to 4,500 feet altitude)Orifice Sizes:Burner Natural Gas #36Burner Propan

Page 18

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 25INSTALLATIONDiagram 1Diagram 5Diagram 2(Use Extreme Caution and ensure properlight off of

Page 19

26 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterCAUTIONAny alteration to the product that caus-es sooting or carboning that resultsin dama

Page 20

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 27WIRING DIAGRAMINSTALLATIONThis heater does not require a 120V A.C. supplyfor operation. In

Page 21

28 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterOPERATING INSTRUCTIONSOPERATINGINSTRUCTIONS1) Read and understand these instructionsbefore

Page 22

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 29COPY OF THE LIGHTING PLATE INSTRUCTIONSOPERATING INSTRUCTIONSAERATION ADJUSTMENTNatural Ga

Page 23

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 3TABLE OF CONTENTSGas Connection ... 24Hi

Page 24

30 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterMAINTENANCEGENERAL VENTMAINTENANCEConduct an inspection of the venting systemsemiannually.

Page 25

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 31REMOVING VALVEASSEMBLY1) Shut off gas supply.2) If optional fan is installed, disconnect p

Page 26

32 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterPARTS LISTMAIN ASSEMBLY Part # Description1) 490-550 Door Assembly-Gold (no glass

Page 27

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 33PARTS LISTBURNER ASSEMBLY & LOG SET Part # Description52) 910-190 Piezo Ignit

Page 28 - OPERATING INSTRUCTIONS

34 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterBASE OPTIONS Part # Description Part # Description490-921 Comp

Page 29

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 35WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. I

Page 30 - MAINTENANCE

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Page 31

4 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterThis is a copy of the label that accompanieseach CLASSIC Direct Vent Freestanding GasStove.

Page 32 - PARTS LIST

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 5IMPORTANT:SAVE THESEINSTRUCTIONSThe CLASSIC Direct Vent Freestanding GasStove must be insta

Page 33

6 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterCLEARANCES TOCOMBUSTIBLESThe clearances listed below are MINIMUM dis-tances. Measure the c

Page 34

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 7Diagram 3Caution: Ensure that the wires do nottouch any hot surfaces.Note: The #8 ground l

Page 35 - WARRANTY

8 Regency CLASSIC C34-2 Direct Vent Freestanding Gas HeaterINSTALLATIONPEDESTAL ASSEMBLY1) For easier assembly, tip the stove on itsback (preferably o

Page 36

Regency CLASSIC C34-2 Direct Vent Freestanding Gas Heater 9INSTALLATIONPRECAUTIONSThese venting systems are engineered prod-ucts that have been design