Regency Ultimate U39-LP1 User Manual

Browse online or download User Manual for Stoves Regency Ultimate U39-LP1. Regency Ultimate U39-LP1 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-531b
MODELS: U39-NG1 Natural Gas U39-LP1 Propane
ULTIMATE U39
Direct Vent Freestanding Gas Stove
01/07/08
Owners &
Installation Manual
www.regency-fi re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - Installation Manual

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury o

Page 2

10Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufacturers may not

Page 3 - TABLE OF CONTENTS

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove11DescriptionSimpsonDirect Vent Pro®Simpson Direct Vent GS®DiscontinuedSelkirk Direct-Temp™Ame

Page 4 - SAFETY LABEL

12Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveRIGID PIPE VENTING SYSTEMSHorizontal or Vertical TerminationsAlternate Horizontal Ter-minati

Page 5 - REQUIREMENTS

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove13INSTALLATION PRECAUTIONSThese venting systems are engineered products that have been designe

Page 6

14Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveHorizontal Venting with Two (2) 90o Elbows Option V H + H1 A) 3' M

Page 7

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove15INSTALLATIONDV STOVE HORIZONTAL VENT KIT INSTALLATIONMinimum Installation Height:U39: 59-3/4

Page 8

16Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATION Note: if the centerline cannot be met, the adjustable sections will have to

Page 9

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove17Alternate Horizontal Termination CapsDura-Vent Basic Horizontal Kit # 9701 90o Elbow1 Wall T

Page 10 - INSTALLATION

18Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveNOTE: For Snorkel terminations in ABOVE grade installations, follow national or local code

Page 11

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove19Diagram 10Diagram 9Diagram 8Diagram 7Diagram 67) Install the Wall Thimble in the center of

Page 12

2Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveREGENCY®ULTIMATE Direct Vent Freestanding Gas StoveTo the New Owner:Congratulations! You are

Page 13

20Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONDiagram 11: The upper half of the fl ashing is installed under the roofi ng materi

Page 14

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove21INSTALLATION Using a level, make sure the support is vertical. If the support extends abo

Page 15

22Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveConverting a Masonry ChimneyImportant: The existing masonry flue opening needs to have an a

Page 16

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove23U39-NG1: For 0 to 2000 feet altitudeU39-LP1: For 0 to 4500 feet altitudeBurner Inlet Orifi ce

Page 17

24Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveCONVERSION KIT# 731-969 FROM NG TO LPTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERI

Page 18

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove2516) Pull off the pilot cap to expose the pilot orifi ce.17) Unscrew the pilot orifi ce with t

Page 19

26Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove7) Reversing step 2 and secure the control panel back onto the stove pedestal with the scre

Page 20

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove27GAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by

Page 21

28Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveAERATION ADJUSTMENTThe burner aeration is factory set but may need adjusting due to either t

Page 22

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove29LOG SET INSTALLATIONINSTALLATIONEmbers EmbersThe "02" refer numbers (i.e. 02-65) a

Page 23

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove3TABLE OF CONTENTSSAFETY LABELCopy of Safety Label ...

Page 24

30Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveCutoutPinD)02-46B)02-56A)02-657) Place the Left Top Log D)02-46 on the pin on Log B)02-56

Page 25

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove31CutoutNotchF)02-47E)02-45A)02-6511) Place the notch in Center Log F)02-47 over Log E)02-4

Page 26

32Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveWIRING DIAGRAMCAUTION: Label all wires prior to disconnection when servicing controls. Wir

Page 27

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove3314 GA.16 GA.18 GA.20 GA.22 GA.50 Ft.32 Ft.20 Ft.12 Ft.9 Ft.Recommended Maximum Lead Length (

Page 28

34Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveOPERATING INSTRUCTIONSSHUTDOWN INSTRUCTIONS1) Use the Burner ON/OFF switch, thermostat or r

Page 29

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove351) Push in gas control knob slightly and turn to “PILOT” position.2) Push in control knob

Page 30

36Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveMAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the valve before cleaning. For religh

Page 31

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove37Mitred Glass ReplacementRemoving Glass1) Remove the door from the unit and place on a soft

Page 32

38Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveMAINTENANCEFAN MAINTENANCEIf your fan requires maintenance or replacement, access to the fan

Page 33

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove39REMOVING VALVE2) Undo the six screws holding the control panel in place.3) Disconnect all

Page 34 - OPERATING INSTRUCTIONS

4Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveThis is a copy of the label that accompanies each ULTIMATE Direct Vent Freestanding Gas Stove

Page 35

40Regency® U39 ULTIMATE Direct Vent Freestanding Gas StovePARTS LIST30) 630-021 Fan Access Panel31) 730-019 Rear Panel32) 730-565 Firebox Baffl e/Re

Page 36 - MAINTENANCE

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove41BURNER & LOG ASSEMBLY51) 910-241 Burner ON/OFF Switch (3-way)52) 910-190 Piezo Ignito

Page 37

42Regency® U39 ULTIMATE Direct Vent Freestanding Gas StovePARTS LISTDOOR ASSEMBLIES Part # Description 730-923

Page 38

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove43WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In

Page 39

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Page 40 - PARTS LIST

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove5REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the follow

Page 41

6Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveIMPORTANT MESSAGESAVE THESE INSTRUCTIONSThe ULTIMATE Direct Vent Freestanding Gas Stove must

Page 42

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove7INSTALLATION8) Any safety glass removed for servicing must be replaced prior to operating th

Page 43 - WARRANTY

8Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveFor Vent Termination requirements, see "Exterior Vent termination Locations" secti

Page 44

Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove9EXTERIOR VENT TERMINAL LOCATIONSA= Clearance above grade, veranda, porch, deck, or balcony *

Comments to this Manuals