WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury o
10Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufacturers may not
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove11DescriptionSimpsonDirect Vent Pro®Simpson Direct Vent GS®DiscontinuedSelkirk Direct-Temp™Ame
12Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveRIGID PIPE VENTING SYSTEMSHorizontal or Vertical TerminationsAlternate Horizontal Ter-minati
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove13INSTALLATION PRECAUTIONSThese venting systems are engineered products that have been designe
14Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveHorizontal Venting with Two (2) 90o Elbows Option V H + H1 A) 3' M
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove15INSTALLATIONDV STOVE HORIZONTAL VENT KIT INSTALLATIONMinimum Installation Height:U39: 59-3/4
16Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATION Note: if the centerline cannot be met, the adjustable sections will have to
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove17Alternate Horizontal Termination CapsDura-Vent Basic Horizontal Kit # 9701 90o Elbow1 Wall T
18Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveNOTE: For Snorkel terminations in ABOVE grade installations, follow national or local code
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove19Diagram 10Diagram 9Diagram 8Diagram 7Diagram 67) Install the Wall Thimble in the center of
2Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveREGENCY®ULTIMATE Direct Vent Freestanding Gas StoveTo the New Owner:Congratulations! You are
20Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveINSTALLATIONDiagram 11: The upper half of the fl ashing is installed under the roofi ng materi
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove21INSTALLATION Using a level, make sure the support is vertical. If the support extends abo
22Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveConverting a Masonry ChimneyImportant: The existing masonry flue opening needs to have an a
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove23U39-NG1: For 0 to 2000 feet altitudeU39-LP1: For 0 to 4500 feet altitudeBurner Inlet Orifi ce
24Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveCONVERSION KIT# 731-969 FROM NG TO LPTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERI
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove2516) Pull off the pilot cap to expose the pilot orifi ce.17) Unscrew the pilot orifi ce with t
26Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove7) Reversing step 2 and secure the control panel back onto the stove pedestal with the scre
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove27GAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by
28Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveAERATION ADJUSTMENTThe burner aeration is factory set but may need adjusting due to either t
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove29LOG SET INSTALLATIONINSTALLATIONEmbers EmbersThe "02" refer numbers (i.e. 02-65) a
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove3TABLE OF CONTENTSSAFETY LABELCopy of Safety Label ...
30Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveCutoutPinD)02-46B)02-56A)02-657) Place the Left Top Log D)02-46 on the pin on Log B)02-56
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove31CutoutNotchF)02-47E)02-45A)02-6511) Place the notch in Center Log F)02-47 over Log E)02-4
32Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveWIRING DIAGRAMCAUTION: Label all wires prior to disconnection when servicing controls. Wir
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove3314 GA.16 GA.18 GA.20 GA.22 GA.50 Ft.32 Ft.20 Ft.12 Ft.9 Ft.Recommended Maximum Lead Length (
34Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveOPERATING INSTRUCTIONSSHUTDOWN INSTRUCTIONS1) Use the Burner ON/OFF switch, thermostat or r
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove351) Push in gas control knob slightly and turn to “PILOT” position.2) Push in control knob
36Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveMAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the valve before cleaning. For religh
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove37Mitred Glass ReplacementRemoving Glass1) Remove the door from the unit and place on a soft
38Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveMAINTENANCEFAN MAINTENANCEIf your fan requires maintenance or replacement, access to the fan
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove39REMOVING VALVE2) Undo the six screws holding the control panel in place.3) Disconnect all
4Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveThis is a copy of the label that accompanies each ULTIMATE Direct Vent Freestanding Gas Stove
40Regency® U39 ULTIMATE Direct Vent Freestanding Gas StovePARTS LIST30) 630-021 Fan Access Panel31) 730-019 Rear Panel32) 730-565 Firebox Baffl e/Re
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove41BURNER & LOG ASSEMBLY51) 910-241 Burner ON/OFF Switch (3-way)52) 910-190 Piezo Ignito
42Regency® U39 ULTIMATE Direct Vent Freestanding Gas StovePARTS LISTDOOR ASSEMBLIES Part # Description 730-923
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove43WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In
Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove5REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the follow
6Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveIMPORTANT MESSAGESAVE THESE INSTRUCTIONSThe ULTIMATE Direct Vent Freestanding Gas Stove must
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove7INSTALLATION8) Any safety glass removed for servicing must be replaced prior to operating th
8Regency® U39 ULTIMATE Direct Vent Freestanding Gas StoveFor Vent Termination requirements, see "Exterior Vent termination Locations" secti
Regency® U39 ULTIMATE Direct Vent Freestanding Gas Stove9EXTERIOR VENT TERMINAL LOCATIONSA= Clearance above grade, veranda, porch, deck, or balcony *