Regency NATURAL GAS U32-NG4 User Manual

Browse online or download User Manual for Kiln Regency NATURAL GAS U32-NG4. Regency NATURAL GAS U32-NG4 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-527
MODELS: U32-NG4 Natural Gas U32-LP4 Propane
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to
this manual. For assistance or additional information consult
an authorized installer, service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
U32 Gas Insert
07/17/06
Owners &
Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.Regency-fi re.com
www.Hampton-fi re.com
www.Palace-fi re.com
TM
Page view 0
1 2 3 4 5 6 ... 39 40

Summary of Contents

Page 1 - U32 Gas Insert

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-527MODELS: U32-NG4 Natural Gas U32-LP4 Propa

Page 2 - FPI GAS INSERT

10 U32-4 FPI Direct Vent Gas Insert6) Place the Left Top Log D)02-46 on the pin on Log C)02-56 and on top of the cutout on Log A)02-43.7) Place the

Page 3 - TABLE OF CONTENTS

11U32-4 FPI Direct Vent Gas InsertDiagram 3Rear View: Trim AssemblyDiagram 2Rear View: Faceplate AssemblyDiagram 1REGENCY FACEPLATE & TRIM INSTALL

Page 4 - SAFETY LABEL

12 U32-4 FPI Direct Vent Gas InsertTo remove the fl ush door, reverse the above steps.NOTE: The chain must rest on TOP of the gas inlet pipe never unde

Page 5 - REQUIREMENTS

13U32-4 FPI Direct Vent Gas InsertBAY LOUVERS1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door.

Page 6

14 U32-4 FPI Direct Vent Gas InsertINSTALLATION THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERIF IN DOUBT DO NOT DO THIS CONVERSION !!1) Shut

Page 7

15U32-4 FPI Direct Vent Gas InsertInstallation of the DC Sparker:16) Verify that if the conversion is from NG to LPG, the screw must be re-assembled

Page 8

16 U32-4 FPI Direct Vent Gas Insert28) Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield. 30)

Page 9

17U32-4 FPI Direct Vent Gas InsertFULL SCREEN DOORSINSTALLATION 1) Hold the full screen door frame up against the unit in order to make the following

Page 10 - INSTALLATION

18 U32-4 FPI Direct Vent Gas InsertINSTALLATION 5) Place Bottom Frame near hinge. Flip hinge over Bottom Frame and secure with 3 screws.4) Install S

Page 11

19U32-4 FPI Direct Vent Gas InsertHAMPTON® CAST FACEPLATE INSTALLATION1) Lay the faceplate panels fl at, face down on something soft so they don'

Page 12

2 U32-4 FPI Direct Vent Gas InsertFPI GAS INSERTNote: Oversize faceplate is 44" x 28"TO THE NEW OWNERCongratulations! You are the owner of

Page 13

20 U32-4 FPI Direct Vent Gas InsertHAMPTON® CAST GRILL INSTALLATIONINSTALLATION Note: The top grill should be placed with the curved cut-out facing up

Page 14

21U32-4 FPI Direct Vent Gas InsertIMPORTANT: Please use the gloves provided when handling the Kensington® Front to avoid fi ngerprints.3) Slide the Ta

Page 15

22 U32-4 FPI Direct Vent Gas InsertTHE KENSINGTON® 2-PANEL DOOR INSTALLATION3) Hook the Left Side Screen Door to the Door Frame by placing the door h

Page 16

23U32-4 FPI Direct Vent Gas InsertOPTIONAL REMOTE CONTROL Use the FPI Remote Control Kit approved for this unit. Use of other systems may void your w

Page 17

24 U32-4 FPI Direct Vent Gas InsertPiezoIgnitorBlackRedToThermocouple INPilotAssemblyThermostat(Optional)(Millivolt)RemoteReceiver(Optional)(Millivolt

Page 18

25U32-4 FPI Direct Vent Gas InsertFor PROPANE Units and Units Equipped with DC Spark Boxes**For installation of the DC Spark Box refer to the LP Conve

Page 19

26 U32-4 FPI Direct Vent Gas InsertThe glass panel may require cleaning after the unit has cooled down. DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS

Page 20

27U32-4 FPI Direct Vent Gas InsertCOPY OF LIGHTING INSTRUCTION PLATEOPERATING INSTRUCTIONSsounds. You should also be aware that as there are temperatu

Page 21

28 U32-4 FPI Direct Vent Gas InsertMAINTENANCEGENERAL VENT MAINTENANCEConduct an inspection of the venting system semi-annually. Recommended areas to

Page 22

29U32-4 FPI Direct Vent Gas InsertFAN MAINTENANCEIf your fan requires maintenance or replacement, access to the fan is through the plate on the rear w

Page 23

3U32-4 FPI Direct Vent Gas InsertTABLE OF CONTENTSFPI GAS INSERTOPERATING INSTRUCTIONSOperating Instructions ...

Page 24

30 U32-4 FPI Direct Vent Gas InsertMAINTENANCEVALVE REPLACEMENT1) Shut off the gas supply.2) Remove the louvers (and bay door if it is on).3) Open

Page 25

31U32-4 FPI Direct Vent Gas InsertPARTS LIST1) 420-122 Fan Access Panel2) 420-142 Gasket - Fan Access Panel 422-518/P Fan Assembly:3) 910-215/P Fa

Page 26 - OPERATING INSTRUCTIONS

32 U32-4 FPI Direct Vent Gas Insert697374715258707290915568676866OTLIPOTHTPTPTHTPTHEAAIRINAIRIN53PARTS LIST 423-574/P Valve Assembly - NG 423-576

Page 27

33U32-4 FPI Direct Vent Gas InsertPARTS LIST Bay Door 420-931 Complete Bay Door with Black Trim102) * Glass Retainer Side (Top & Btm)1

Page 28 - MAINTENANCE

34 U32-4 FPI Direct Vent Gas InsertLOGOPLATEHERELOGOPLATEHERELOGOPLATEHERELOGOPLATEHERE9295STANDARD SIZEDETAIL 'A'9193REAR VIEWFRONT VIEW966

Page 29

35U32-4 FPI Direct Vent Gas Insert202205187189188203195194194207201 402-971** Cast Faceplates (Set)187) 910-246 Burner On/Off Switch188) 910-330 Fa

Page 30

36 U32-4 FPI Direct Vent Gas InsertNOTES______________________________________________________________________________________________________________

Page 31 - PARTS LIST

37U32-4 FPI Direct Vent Gas InsertNOTES_______________________________________________________________________________________________________________

Page 32

38 U32-4 FPI Direct Vent Gas InsertNOTES______________________________________________________________________________________________________________

Page 33

39U32-4 FPI Direct Vent Gas InsertWARRANTYFPI Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quali

Page 34

4 U32-4 FPI Direct Vent Gas InsertSAFETY LABELThis is a copy of the labels that accompany each U32-4 Gas Insert. We have printed a copy of the content

Page 35

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Page 36

5U32-4 FPI Direct Vent Gas InsertREQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional requireme

Page 37

6 U32-4 FPI Direct Vent Gas InsertIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe FPI Gas Insert must be installed in accordance with these instruction

Page 38

7U32-4 FPI Direct Vent Gas InsertABDECMANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS1) Ensure that structural members are not cut or weakened durin

Page 39 - WARRANTY

8 U32-4 FPI Direct Vent Gas InsertVENTINGTHE APPLIANCE MUST NOT BE CONNECTED TO ACHIMNEY FLUE SERVING A SEPARATE SOLID FUELBURNING APPLIANCE.This appl

Page 40 - and Palace

9U32-4 FPI Direct Vent Gas InsertOPTIONAL BRICK PANEL1) Unwrap the brick pattern panels from the protective wrapping.2) Remove the glass front if it

Related models: NATURAL GAS U32-LP4

Comments to this Manuals