Regency Classic C34 Small Gas Stove User Manual

Browse online or download User Manual for Radiators Regency Classic C34 Small Gas Stove. Regency Classic C34 Small Gas Stove User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
WARNING:
If the information in these instructions are not followed ex-
actly, a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your build-
ing.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas sup-
plier, call the re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-512a
MODELS: C34-NG3 Natural Gas C34-LP3 Propane
C34 Classic Direct Vent
Freestanding Gas Stove
Classic C34 model shown above features optional
gold plated door and gold legs.
04/12/11
Owners &
Installation Manual
www.regency- re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - Freestanding Gas Stove

WARNING: If the information in these instructions are not followed ex-actly, a fi re or explosion may result causing property damage, personal injury

Page 2 - To the New Owner:

10Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONCOMBUSTION AND VENTILATION AIRThe combustion air from this appliance is drawn f

Page 3

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove11INSTALLATIONDiagram 3Caution: Ensure that the wires do not touch any hot surfaces.Note: Th

Page 4 - DIMENSIONS

12Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONPEDESTAL ASSEMBLY1) For easier assembly, tip the stove on its back (preferably

Page 5 - TABLE OF CONTENTS

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove13INSTALLATIONINSTALLATION PRECAUTIONSThese venting systems are engineered products that have

Page 6 - SAFETY LABEL

14Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONEXTERIOR VENT TERMINAL LOCATIONSMinimum Clearance RequirementsCanada1USA2A Clea

Page 7 - REQUIREMENTS

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove15INSTALLATION4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufactu

Page 8

16Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Ame

Page 9

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove17INSTALLATIONPipe LengthVerticalTerminationCapStorm CollarFlashingCeiling Firestop24" P

Page 10 - INSTALLATION

18Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONVENTING ARRANGEMENTS VERTICAL TERMINATION SYSTEMS FOR RESIDENTIAL MANUFACTURED

Page 11

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove19INSTALLATIONHorizontal Venting with Two (2) 90o Elbows Option V H + H1 A

Page 12

2Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveREGENCYClassic Direct Vent Freestanding Gas StoveTo the New Owner:Congratulations! You are t

Page 13

20Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONDV STOVE HORIZONTAL VENT KIT (#946-116 & #946-216) INSTALLATIONDV STOVE HOR

Page 14

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove21INSTALLATION e) Cut the 2 ft. or 4 ft. section of rigid pipe to length. Ensure that the p

Page 15

22Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONDURA-VENT TERMINATION KITPlanning Your Dura-Vent InstallationThere are two basi

Page 16

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove23INSTALLATIONDiagram 4Below Grade InstallationIf the Snorkel Termination must be installed b

Page 17

24Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONDiagram 9the roof. Deter-mine if ceiling joists, roof raft-ers or other fram-in

Page 18

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove25INSTALLATIONCATHEDRAL CEILINGSRound Support (RDS) & Square Support (SQS)If your home ha

Page 19

26Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONSupport extensions - Round (RDSE) or square (SQSE)Steep pitched cathedral ceili

Page 20

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove27INSTALLATION7) The connection between the appliance and the Retro Connector may be complet

Page 21

28Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONSYSTEM DATA(For 0 to 4,500 feet altitude)Orifi ce Sizes: Burner Natural Gas #36

Page 22

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove29INSTALLATIONVALVE DESCRIPTION1) Gas on/off knob2) Manual high/low adjustment3) Pilot Adju

Page 23

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove3This Regency® Mobile/Manufactured Home listed appliance comes equipped with a dedicated #8 g

Page 24

30Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONDiagram 1Diagram 5Diagram 2Note: If the fl ame hesitates at any point, check the

Page 25

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove31INSTALLATIONCAUTIONAny alteration to the product that causes sooting or carboning that resu

Page 26

32Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONWIRING DIAGRAMSThis heater does not require a 120V A.C. sup-ply for operation.

Page 27

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove33INSTALLATIONCAUTION: Label all wires prior to disconnection when servicing controls. Wiring

Page 28

34Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove34OPERATING INSTRUCTIONSOPERATING INSTRUCTIONS1) Read and understand these instructions be

Page 29

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove3535INSTALLATIONOPERATING INSTRUCTIONSCOPY OF THE LIGHTING PLATE INSTRUCTIONS 1) Push in gas

Page 30

36Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONGENERAL VENT MAINTENANCEConduct an inspection of the venting system semiannuall

Page 31

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove37MAINTENANCEREMOVING VALVE ASSEMBLY1) Shut off gas supply.2) If optional fan is installed,

Page 32

38Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StovePARTS LIST312420131419DOOR6722FAN ASSEMBLY (OPTIONAL)41538303132333526372625262728244026117

Page 33

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove39PARTS LISTBURNER ASSEMBLY & LOG SET Part # Description

Page 34 - OPERATING INSTRUCTIONS

4Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveDIMENSIONS

Page 35

40Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StovePARTS LISTBASE OPTIONS Part # Description Part #

Page 36

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove41NOTES

Page 37 - MAINTENANCE

42Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveNOTES

Page 38 - PARTS LIST

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove43WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In

Page 39

Printed in Canada © Copyright 2011, FPI Fireplace Products International Ltd. All rights reserved.Regency and Classic are trademarks of FPI Fireplace

Page 40

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove55TABLE OF CONTENTSSAFETY LABELSerial No. Decal...

Page 41

6Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveSAFETY LABELThis is a copy of the label that accompanies each CLASSIC Direct Vent Freestandi

Page 42

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove7REQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the follow

Page 43 - WARRANTY

8Regency® CLASSIC C34-3 Direct Vent Freestanding Gas StoveINSTALLATIONCLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIAN

Page 44 - warranty online

Regency® CLASSIC C34-3 Direct Vent Freestanding Gas Stove9INSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe CLASSIC Direct Vent Freestanding G

Comments to this Manuals