Regency P33 SunriseTM P33S-LP4 User Manual

Browse online or download User Manual for Kiln Regency P33 SunriseTM P33S-LP4. Regency P33 SunriseTM P33S-LP4 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
WARNING:
If the information in these instructions are not followed exactly,
a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-757
Regency P33 Sunrise
Gas Fireplace
11/05/08
Owners &
Installation Manual
www.regency- re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
MODEL: P33S-NG4 Natural Gas
P33S-LP4 Propane
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - Gas Fireplace

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury o

Page 2 - To the New Owner:

Regency P33 SunriseTM Gas Fireplace10INSTALLATIONINSTALLATIONMANTEL CLEARANCESNote: Ensure the paint that is used on the mantel and the facing is &qu

Page 3 - TABLE OF CONTENTS

Regency P33 SunriseTM Gas Fireplace 11INSTALLATIONINSTALLATIONNote: When constructing the framed opening, please ensure there is access to install th

Page 4 - SAFETY LABEL

Regency P33 SunriseTM Gas Fireplace12INSTALLATIONGHIIMJLKPQON10" (254mm)dia. Hole throughwall Vent.Opening for gasconnectionTop Header.Wood, dryw

Page 5 - REQUIREMENTS

Regency P33 SunriseTM Gas Fireplace 13INSTALLATIONINSTALLATIONBeforeAfterBendhereTop Standoff(flat shippingposition)Top Standoffafter bendingThe Top F

Page 6 - DIMENSIONS

Regency P33 SunriseTM Gas Fireplace14INSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTSINSTALLATIONA= Clearance above grade, veranda, porch, deck, or

Page 7

Regency P33 SunriseTM Gas Fireplace 15INSTALLATIONWherever necessary due to external location of cap, the AstroCap can be replaced with the FPI Riser

Page 8

Regency P33 SunriseTM Gas Fireplace16INSTALLATIONINSTALLATIONPipe LengthVerticalTerminalStorm CollarFlashingCeiling FirestopAdj.Pipe Length11" -

Page 9 - Close to Ceiling

Regency P33 SunriseTM Gas Fireplace 17INSTALLATIONINSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect-Temp™American MetalProducts®Amerivent Di

Page 10 - INSTALLATION

Regency P33 SunriseTM Gas Fireplace18INSTALLATIONINSTALLATIONDescriptionSimpsonDirect Vent Pro®Selkirk Direct-Temp™American Metal Products®Amerivent D

Page 11

Regency P33 SunriseTM Gas Fireplace 19INSTALLATION• Vent must be supported at offsets.• Firestops are required at each fl oor level and whenever pa

Page 12

Regency P33 SunriseTM Gas Fireplace2To the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The P33 Sunri

Page 13

Regency P33 SunriseTM Gas Fireplace20INSTALLATIONINSTALLATIONFlex LinerExhaustFlueA maximumof two certifiedjoiner kitsmay be usedper length.#948-30535

Page 14

Regency P33 SunriseTM Gas Fireplace 21INSTALLATIONINSTALLATIONVENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for bothResident

Page 15

Regency P33 SunriseTM Gas Fireplace22INSTALLATIONINSTALLATION162468101214200122061430” (762mm)MinimumHeightRequirement48101816Vertical Height (Feet)Ho

Page 16

Regency P33 SunriseTM Gas Fireplace 23INSTALLATIONINSTALLATIONHorizontal Venting with Two (2) 90o ElbowsHorizontal Venting with Three (3) 90o ElbowsOn

Page 17

Regency P33 SunriseTM Gas Fireplace24INSTALLATIONINSTALLATIONHorizontal Venting with Three (3) 90o ElbowsVertical Venting with Two (2) 90o ElbowsVerti

Page 18

Regency P33 SunriseTM Gas Fireplace 25INSTALLATIONINSTALLATIONVertical Venting with Three (3) 90o ElbowsVertical Venting with Three (3) 90o Elbows

Page 19 - Maximum 35’ (10.6m)

Regency P33 SunriseTM Gas Fireplace26INSTALLATIONRiser VentTerminationMin. 6-1/4"*(159mm)Diagram 3UNIT INSTALLATION WITH HORIZONTAL TERMINATIONDi

Page 20

Regency P33 SunriseTM Gas Fireplace 27INSTALLATIONGAS LINE INSTALLATIONThe gas line is brought through the right side of the appliance. The gas valve

Page 21

Regency P33 SunriseTM Gas Fireplace28INSTALLATIONINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system

Page 22

Regency P33 SunriseTM Gas Fireplace 29INSTALLATIONCONVERSION KIT# 434 - 970 FROM NG TO LPFor P33 Sunrise™ Using SIT 820 NOVA Gas ValveTHIS CONVERSION

Page 23

Regency P33 SunriseTM Gas Fireplace 3TABLE OF CONTENTSSAFETY LABELCopy of Safety Decal ...4REQUIREME

Page 24

Regency P33 SunriseTM Gas Fireplace30INSTALLATIONINSTALLATIONWARNING!Do not overtighten the screw. Recommended to gripthe wrench by the short side.9)

Page 25

Regency P33 SunriseTM Gas Fireplace 31INSTALLATIONINSTALLATIONDC SPARK BOX REPLACEMENTDC SPARK BOX BATTERY REPLACEMENT1) Remove the faceplate by lift

Page 26

Regency P33 SunriseTM Gas Fireplace32INSTALLATIONWALL SWITCH1) Run the supplied wire through the right or left side gas inlet opening. Be careful no

Page 27

Regency P33 SunriseTM Gas Fireplace 33INSTALLATIONWIRING DIAGRAM AERATION ADJUSTMENTThe burner aeration is factory set but may need adjusting due to e

Page 28

Regency P33 SunriseTM Gas Fireplace34INSTALLATIONINSTALLING THE OPTIONAL FAN120 Volt AC power is needed for the fan switch and blower. The fan can be

Page 29

Regency P33 SunriseTM Gas Fireplace 35INSTALLATIONINSTALLATIONOPTIONAL STAINLESS STEELREFLECTIVE PANEL INSTALLATION1) If already installed, remove t

Page 30

Regency P33 SunriseTM Gas Fireplace36INSTALLATIONGLASS CRYSTALINSTALLATION ON BURNEROPTIONAL PEBBLE INSTALLATION ON FIREBOX BASEINSTALLATIONSpread the

Page 31

Regency P33 SunriseTM Gas Fireplace 37INSTALLATIONINSTALLATIONGLASS DOOR INSTALLATIONSTANDARD FLUSH DOORThe standard fl ush door comes with a black fra

Page 32

Regency P33 SunriseTM Gas Fireplace38INSTALLATIONFACEPLATE INSTALLATIONINSTALLATION1) Install the control shield with 2 #8 - 1/2" Phillips screw

Page 33

Regency P33 SunriseTM Gas Fireplace 39INSTALLATIONINSTALLATIONDiagram 7Diagram 8Diagram 9FaceplateFaceplate Support6) Hook the fl ange on the facepla

Page 34

Regency P33 SunriseTM Gas Fireplace4INSTALLATIONSAFETY LABELThis is a copy of the label that accompanies each P33 Sunrise™ Direct Vent Gas Fireplace.

Page 35

Regency P33 SunriseTM Gas Fireplace40OPERATIONOPERATING INSTRUCTIONS1) Read and understand these instructions before operating this appliance.2) Che

Page 36

Regency P33 SunriseTM Gas Fireplace 41OPERATIONOPERATING INSTRUCTIONSCOPY OF LIGHTING PLATE INSTRUCTIONSTO TURN OFF GAS APPLIANCEFOR YOUR SAFETY READ

Page 37

Regency P33 SunriseTM Gas Fireplace42MAINTENANCEMAINTENANCEMAINTENANCE INSTRUCTIONS1) Always turn off the gas valve before cleaning. For relighting,

Page 38

Regency P33 SunriseTM Gas Fireplace 43MAINTENANCEVALVE TRAY REPLACEMENTMAINTENANCEREMOVING VALVE1) Shut off the gas supply.2) Remove the faceplate.3

Page 39

Regency P33 SunriseTM Gas Fireplace44PARTS LISTPARTS LISTMAIN ASSEMBLY Part # Description 434-907 Refl ective P

Page 40 - OPERATING INSTRUCTIONS

Regency P33 SunriseTM Gas Fireplace 45PARTS LISTPARTS LIST8102421191620153121823174FAN SWITCH ASSEMBLY2528292730132214MAIN ASSEMBLY

Page 41

Regency P33 SunriseTM Gas Fireplace46NOTES

Page 42 - MAINTENANCE

Regency P33 SunriseTM Gas Fireplace 47WARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our inter

Page 43

Regency P33 SunriseTM Gas Fireplace48Installer: Please complete the following informationDealer Name & Address: __________________________________

Page 44 - PARTS LIST

Regency P33 SunriseTM Gas Fireplace 5INSTALLATIONREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following addit

Page 45

Regency P33 SunriseTM Gas Fireplace6INSTALLATIONDIMENSIONSUNIT DIMENSIONS

Page 46 - Gas Fireplace

Regency P33 SunriseTM Gas Fireplace 7INSTALLATIONbe removed for servicing should be replaced prior to operating this appliance.12) Installation and an

Page 47 - WARRANTY

Regency P33 SunriseTM Gas Fireplace8INSTALLATIONINSTALLATIONThis includes:1) Clocking the appliance to ensure the correct fi ring rate (rate noted on

Page 48

Regency P33 SunriseTM Gas Fireplace 9INSTALLATIONINSTALLATIONCaution RequirementsThe top, back and sides of the fi replace are defi ned by standoffs. Th

Related models: P33 SunriseTM P33S-NG4

Comments to this Manuals

No comments